29
CLEAN WASTE PUMP-OUT PUMP: (if so equipped)
Build-up of fine silt inside the optional Waste Pump can clog the pump even if the pump is not used, so this
maintenance procedure should be performed regardless of whether the Waste Pump has been used.
•
After cleaning out the recovery tank, remove the cap and
connect the Pump-Out hose to the Waste Pump outlet
fitting on the back of the machine; run the hose to a drain.
•
Open the drain valve and use a hose to rinse off the Pump-
Out pump and Float Switch.
•
Close the drain valve and fill the recovery tank
approximately 1/2 full with clean water.
•
With Cord #2 plugged in, turn the Waste Pump switch to
the ON position. Lift up and hold the float switch to
activate the pump.
•
Let the pump run until it pumps the level down to the
point below close to the bottom of the pump.
•
Unplug the cord and turn the Waste Pump switch OFF.
•
Open the drain valve and drain out the remaining water.
•
Close the drain valve, replace the recovery tank lid, and dispose of the dirty water and debris.
FLUSH SOLUTION TANK AND PUMP:
•
Pour two or three gallons of clean water into the solution tank.
•
With Cords #1 & #2 plugged in, connect the pump prime hose to the
solution outlet female quick connect.
•
Direct the end of the pump priming hose into the recovery tank vacuum
barb.
•
Turn one or both of the vacuums ON and turn the solution pump ON.
•
Let the pump run until most of the water has been pumped out of the
solution tank.
Do not let the pump run dry. Turn the pump OFF
before the water gets to the bottom of the tank.
•
Turn the vacuums OFF and disconnect the prime hose.
•
Place a bucket under the drain valve; open the drain valve to drain the water out of the recovery tank.
•
Close the drain valve and dispose of the water.
If there is a heavy chemical build-up in the machine, hoses, or tools, a mild acid can be added to the rinse
water in the previous procedure (REFER TO PHOTOS ON FOLLOWING PAGE.)
•
After the pump has been primed, turn the solution pump switch OFF and turn the vacuums OFF.
•
Remove the pump priming hose and connect the solution hose and tools.
•
Turn the solution pump ON and direct the tool spray into a bucket. Let the pump run until most of
the water has been pumped out of the solution tank.
Do not let the pump run dry.
Turn the pump OFF before the water gets to the bottom of the tank.
Pour 2 or 3 gallons of clean
water into Solution Tank
Summary of Contents for Extreme MXE-200
Page 1: ...1 LMANN08 Revised 01 29 2015 Nautilus MXE 200 Operating Manual EXTREME ...
Page 23: ...23 M1200 Wiring Diagram Nautilus MXE 200 Wiring Diagram Cord 1 ...
Page 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Page 38: ...38 Pump Out Pump PARTS ASSEMBLY ...
Page 39: ...39 1 4 4 6 7 8 9 10 11 3 3 8 9 12 8 9 39 8 9 2 2 5 ...
Page 49: ...49 92 91 95 94 112 13 14 14A 104 105 1 39 PUMP OUT CONNECTIONS ...
Page 50: ...50 35 36 36A 78 36 36A 34 39 127 128 129 2 1 130 32 34 119 39 131 ...