22
Problem
Cause
Solution
Solution Tank Water source turned off
Turn on faucet or find other water source
not filling
Float not on valve arm
Reconnect float to valve arm - Adjust to proper height/level
Float valve faulty
Repair or replace float valve
Water hose restricted
Un-kink, clean out or replace hose
Water Pressure too high
Use pressure regulator on auto-fill hose
Quick connects faulty
Clean out or replace quick connects (AH101B, AH102B)
Solution tank
Float too heavy/ Filled with water
Replace float
overflowing
Float & chain tangled
Make sure float chain free & hanging properly
Float too high
Adjust chain to set float at proper level
Water Pressure too high
Use pressure regulator on auto-fill hose
Float valve faulty
Repair or replace float valve
Chemical Jug
Foot valve in Filter stuck
Clean out foot valve and filter
Filling with
Foot valve in Filter faulty
Replace foot valve and filter (PDE100-11P)
water -
Overflowing
*
: To reduce the risk of fire electrical shock or injury repairs to wiring should only be
performed by experienced service technicians.
If you are not experienced in checking electrical wiring contact your nearest authorized service
center to perform tests and repairs to wiring and switches.
•
Contact your distributor for additional troubleshooting
assistance, to order parts, or for advice and assistance in
performing necessary repairs.
Summary of Contents for MX3-1200E
Page 1: ...1 LMANN12 Revised 01 29 2015 Nautilus MX3 1200E Operating Manual...
Page 39: ...39 NM5740 AUTO FILL FLOAT VALVE ASSEMBLY...
Page 41: ...41 Pump Out Pump AP37F PARTS ASSEMBLY...
Page 42: ...42 1 2 3 5 4 4 6 7 8 9 10 39 8 3 8 9 11 12 23 100 104 2 9 8 9...
Page 49: ...49 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK...
Page 51: ...51 PUMP OUT CONNECTIONS 96 88 112 105 93 99 96 91 95 97 9 111 113 117 103...
Page 52: ...52 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 PUMP OUT PARTS 1 39 103 9 97...