32
FLUSH CHEMICAL SYSTEM: (If so equipped)
Chemical build-up in the optional Auto Fill chemical system can prevent the system from drawing chemical.
•
Rinse the chemical system with fresh water (For heavy chemical build-up, a mild acid can be added to the
rinse water.)
•
Remove the chemical feed hose from the solution tank and place the end of the hose in a bucket of fresh
water or mild acid solution.
•
Connect the Auto-Fill Water Supply Hose to the water inlet (male quick connect) on the front of the
machine.
•
Connect the other end of the hose to a water faucet and turn on the water. Let the water flow into the
tank until you are sure the rinse solution has been drawn through the proportioner and mixed with the
incoming water. The metering tip can be removed from the proportioner to speed up the process.
•
Once the rinse solution has been drawn through the proportioner, turn off the water faucet and
disconnect the Auto-Fill Water Supply Hose.
•
Plug in Cords, connect the vacuum hose to the vacuum barb, turn on one or both vacuums, and use the
vacuum hose to remove the water from the solution tank.
•
When the solution tank has been emptied, turn off the vacuums and unplug the power cord.
•
Place a bucket under the drain valve and open the drain valve to drain the water from the recovery tank.
•
Close the drain valve and dispose of the water.
Place Chemical Feed Hose into
Rinse Solution
Connect Auto-Fill Water Supply
Hose to machine and faucet
Vacuum water out of Solution
Tank
Drain water from Recovery
Tank
Summary of Contents for MX3-500RP
Page 1: ...1 LMANN14 Revised 06 04 2014 Nautilus MX3 500RP Operating Manual...
Page 38: ...38 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740...
Page 40: ...40 Pump Out Pump PARTS ASSEMBLY...
Page 41: ...41 1 2 3 5 4 4 6 7 8 9 10 11 12 3 8 9 8 9 8 9 39 2...
Page 48: ...48 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK...
Page 50: ...50 92 91 95 94 112 13 14 14A 104 105 1 39 PUMP OUT CONNECTIONS...