Waypoint
Uploading Waypoints from a Personal Computer
You can use any terminal or communications program to download or
upload waypoints and routes to or from the CDU and a PC.
Set the PC to:
4800 baud
8 bits
1 stop bit
no parity
no flow control
When sending data to the CDU, it must be sent in block form, followed
by (with an appended) CR (carriage return) and LF (line feed). Normal
communications programs, like
Windows 3.1
or
3.11 Terminal
are suf-
ficient to get the job done. Unfortunately
Windows 95 and new Win-
dows O/S
doesn’t provide a basic terminal emulation program; there-
fore, a third party program is required with
Windows 95
and abive.
Using
Windows Terminal
, do the following (from the
Program Man-
ager
):
1. Connect the CDU’s port 2 RS-232 port to the PC’s communications
port (Refer to the
Installation & Service Manual
).
2. On the CDU press the
CFG
key until
CFG1
screen is displayed.
3. Scroll down the menu to
WPL Input.
4. Press the
E
key.
5. Set the
Transducer Connected
to
Yes.
6. Set the
Data Input Port No.
to 2.
7. Press the
E
key.