60 Operating the Boiler
11.4.6 Viewing Error History
To view the error history, press the Menu button (
), and then
select “6. Error History”.
A list of 10 recent errors are displayed on the screen, with the
most recent error displayed at the top of the list.
Rotate the Command dial (
) to switch between the list of
errors. Press the Command dial (
) to select an error to view
detailed information.
Press the Back button (
) to return to the previous screen or
menu.
Note
Ɣ
The front panel display flashes in red and the error
icon is displayed (flashing) when a level 1 error is
detected. You can press the Command dial (
)
to enter error display mode. Boiler operation is
maintained during a level 1 error.
Ɣ
A level 1 error is automatically cleared when the
problem is resolved.
Ɣ
You can press the Power button (
) to clear a
level1 error. Then the error is cleared if the problem
has been resolved.
Combi Models - Central Heating Mode
Item
Description
1. 7 Day
Schedule a command for each day of
the week.
2. 5 + 2 Day
Schedule a command for weekday
and weekend.
3. 5 + 1 + 1 Day
Schedule a command for weekdays,
Saturdays, and Sundays.
4. OFF (Not Used)
Disable the schedule function.
Combi Models - DHW Mode
Item
Description
1. Always On
Preheat always ON.
2. Intelligent
The boiler analyzes your hot water
consumption pattern and preheats
the water when the set conditions
are met.
3. Weekly
Set the DHW mode settings to be the
same as space heating mode.
4. OFF (Not Used)
Disable the schedule function.
Set the Weekly Schedule
When setting up the Weekly option, select ‘Weekly,’ and select
between 1 Day, 3 Day, and 7 Day to go to the Schedule menu.
Not working
Working
Rotate the Command Dial (
) to choose the scheduled time.
You can choose the time in 30 minutes intervals.