39
Example of installation of the oil pipe (
K
PO Burner)
1
. Multi piping system (2-pipe type)
2.
S
ingle piping system (
1
-pipe type)
Use this method when the oil tank is installed
above or at the same height as the boiler.
As the boiler is initially set at the multiple
piping system, refer to the modification method
of the gear pump, in order to modify the
multiple piping to the single piping system.
Use this system when the oil tank is installed
above, below, or at the same height as the
boiler.
The piping method is to connect the gear
pump inlet to the pipe on the lower side of
the oil tank and connect the additional return
pipe to the return pipe of the gear pump in
order to return the oil to the tank.
3. The method of modification of the gear pump
(Multiple piping system
Ą
single piping system)
DANFOSS:
SUNTEC:
Η
Disassemble the oil hose for return, and assemble A.
Θ
Open the bolt B and remove the inner screw using a regular screwdriver (-)
and reassemble the bolt B.
Η
Disassemble the oil hose for return and remove the screw using the Allen
wrench. Then, assemble the bolt A.
4. In the multiple piping system, the parts
1
, 2, and 3 are supplied in an
assembly, and the parts 4,
5
, and
6
and the bolt A are supplied separately
in the parts’ pocket.
<DANFOSS>
<SUNTEC>
Summary of Contents for LST-58K
Page 1: ...LST 58K...
Page 2: ......
Page 11: ...The structure and its description 11 Boiler LST 58K...
Page 28: ...Outside drawing on the boiler 29 LST 58K...
Page 42: ...43 Standard piping drawing Open expansion Combi boiler Closed expansion Combi boiler...
Page 51: ...55 Electric wiring diagram IU08 2 IU0 D 2 OFU05G IU08K DU06P...
Page 53: ...memo 57...
Page 54: ...58 memo...
Page 55: ......