background image

WARNING

If the information in these instructions is not followed exactly, a fire or explosion may result, causing 
property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 
appliance.

What to do if you smell gas

 

Do not try to light any appliance.

 

Do not touch any electrical switch; do not use any phone in your building.

 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

 

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code, 
ANSIZ223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Code.

H

NSF/ANSI 372

Keep this manual near this boiler for future reference whenever 
maintenance or service is required.

*  The wetted surface of this product contacted by consumable water contains less than 

one quarter of one percent (0.25%) of lead by weight.

Installation & Operation Manual

NCB-E Condensing Combi-Boilers

Model

NCB-150E
NCB-180E
NCB-210E
NCB-240E

Summary of Contents for NCB-150E

Page 1: ...f you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier The installation must conform with...

Page 2: ...72 Appendixes 11 4 Component Assembly Diagrams and Parts Lists 11 4 1 Case Assembly 2 1 4 5 6 7 8 3...

Page 3: ...on Part Remark 1 Intake Air Duct Assembly 30008662B 2 Exhaust Pipe Assembly 30008673A 3 Case 20033278A 4 Intake Air Filter 20007668A 5 Air Pressure Sensor 30010346A 6 PCB 30012262A 7 Front Panel 30012...

Page 4: ...74 Appendixes 11 4 2 Burner Assembly 1 2 9 10 11 12 13 14 21 18 17 4 20 13 19 12 10 16 15 3 6 5 7 8...

Page 5: ...22A NCB 180E 30012321A NCB 210E 30012317A NCB 240E 9 Thermistor Exhaust 30009478A 10 Thermistor Water 30008366A 11 High Limit Switch 30002558A 12 Fastener 20007859A 13 O Ring P19 20017211A 14 Heat Exc...

Page 6: ...16 2 36 21 32 3 33 30 24 23 19 19 37 27 13 19 25 29 6 26 22 21 3 20 16 35 31 35 16 18 3 2 1 3 22 Description Part Remark 1 DHW Heat Exchanger 30015581A NCB 150E 30008181A NCB 180E 30005017A NCB 210E 2...

Page 7: ...ptor B 30012332A 19 Fastener 20017726A 20 3 Way Outlet Adaptor A 30012331A 21 Packing 20011380A 22 Connection Adaptor 20011408A 23 3 Way Valve 30004831B 24 Fastener 20007733A 25 Water Fill Pipe 300122...

Page 8: ...78 Appendixes 11 4 4 Fan Gas Assembly 2 4 7 5 6 11 14 12 11 10 9 13 11 15 1 3 8...

Page 9: ...NCB 150E 20023861A NCB 180E 20019141A NCB 210E 240E 7 Venturi Packing 20022660A NCB 180E 8 Gas Orifice 20033737A NCB 150E 20024159A NCB 180E NG 20019144B NCB 210E 240E NG 20034176A NCB 150E LP 2002419...

Page 10: ...list the default space heating temperature range by system heat load and the applicable outdoor temperature ranges 11 5 OutdoorTemperature Sensor Optional OutdoorTemperature Sensor Installation 1 Pull...

Page 11: ...Low Mass Radiant 80 140 F 26 5 60 C 70 116 F 21 46 5 C High Mass Radiant 80 120 F 26 5 48 5 C 70 101 F 21 38 C Radiators 120 170 F 48 5 76 5 C 101 139 F 38 59 C Custom Supply Control Absolute MIN MAX...

Page 12: ...Memo...

Page 13: ...licensed professional for the affected system for example a plumber or electrician When you contact Technical Support please have the following information at hand Model number Serial number Date pur...