98 NCB Service Manual
Version 1.0
Check method
Fault
Possible Causes
Check method
Fan action error
No fan operation
1.
Check the power supply to the blower.
Black+Red, approx. DC 127~184 V
2.
Replace the PCB if voltages are abnormal. (When replacing the PCB, turn off the
unit and then wait for at least 10 seconds before proceeding.)
3.
If the issue continues despite the checking the items above, replace the fan
motor.
Check if the fan motor wire is disconnected
Fan motor RPM
error
Defective rotator
1.
If RPM is significantly low while the fan is operating and the power supply is
normal. Follow the instructions listed below and replace the fan.
1) Unplug the power cable to the unit and then wait for 10 seconds until the
remaining SMPS voltage completely discharges.
2) Disconnect the fan cable and then re-connect it.
3) Plug the power cable and turn on the unit.
4) Fan Auto Adjusting verifies error conditions for error code E109. If an E109 error
occurs, enter the Fan Test Mode and verify fan RPM and APS input
voltage.(Display: ex. H.320 = 3200 RPM)
5) If RPM is low or there is a sensor circuit error, replace the fan.
Indicates an imminent hazardous situation which, if not avoided, may result in
minor or moderate injury.
2.
If the issue continues despite checking the items above, replace the PCB.
Summary of Contents for NCB-180
Page 3: ......
Page 16: ......
Page 135: ...132 NCB Service Manual Version 1 0 7 2 Burner Assembly...
Page 139: ...136 NCB Service Manual Version 1 0 7 4 Fan Gas Assembly...
Page 142: ...Memo...
Page 143: ...140 NCB Service Manual Version 1 0 Memo...
Page 144: ...Memo...
Page 145: ...142 NCB Service Manual Version 1 0 Memo...
Page 146: ...Memo...
Page 147: ...144 NCB Service Manual Version 1 0 Memo...
Page 148: ...Memo...