42 NCB Service Manual
Version 1.0
4.4.10 information display (for servicer)
1.
At the <Normal operation mode>, press the [Diagnostic] button once for 5 seconds to access the service information display.
2.
Whenever the [+] / [-] button is pressed, the Information Data items are increased/decreased and displayed.
3.
The current Information Data item is identified with a letter prefix followed by 3 digits of the relevant data.
4.
Press the [Reset] button once to return to the <Normal operation mode>.
5.
If there is no button input for 1 hour, then it automatically returns to the <Normal operation mode>.
Item
Description
Display
(A) Space heating supply
water temperature
Display of the current space heating
outgoing water temperature
For Celsius (
℃
) mode; ex) at 60
℃
For Fahrenheit (
℉
) mode; ex) 120
℉
(B) Space heating return
water temperature
Display of the current space heating
incoming water temperature
For Celsius (
℃
) mode; ex) at 60
℃
For Fahrenheit (
℉
) mode; ex) 120
℉
(C) Domestic hot water outlet
temperature
Display of the current outgoing water
temperature
For Celsius (
℃
) mode; ex) at 60
℃
For Fahrenheit (
℉
) mode; ex) 120
℉
(D) Cold water inlet
temperature
Display of the current incoming water
temperature
For Celsius (
℃
) mode; ex) at 15
℃
For Fahrenheit (
℉
) mode; ex) 59
℉
Summary of Contents for NCB-180
Page 3: ......
Page 16: ......
Page 135: ...132 NCB Service Manual Version 1 0 7 2 Burner Assembly...
Page 139: ...136 NCB Service Manual Version 1 0 7 4 Fan Gas Assembly...
Page 142: ...Memo...
Page 143: ...140 NCB Service Manual Version 1 0 Memo...
Page 144: ...Memo...
Page 145: ...142 NCB Service Manual Version 1 0 Memo...
Page 146: ...Memo...
Page 147: ...144 NCB Service Manual Version 1 0 Memo...
Page 148: ...Memo...