Item
Description
Display
(Q) Model and Capacity
Currently set model and capacity
display
The 2nd & 3rd digits represent the
model and the 4th digit represents the
type of market.
ex) Capacity 180, condensing for the American
market
ex) Capacity level 240, for the Korean market
ex) Setting error
(R) Information on Gas Type
Display of current gas
NG
LP
(S) Altitude setting
information
Display of current altitude level setting
0~2,000ft
2,000~5,400ft
5,400~7,700ft
7,700~10,100ft