5.2.3 012Error
Error occurrence conditions and check items
Error
Description
E012
Flame loss
If the system detects loss of flame during combustion, the system stops supplying fuel, attempts to restart,
counts the incidents of flame loss, and if the incident occurs 20 times consecutively displays 012E (manually
cleared) on the front panel.
Check items
1.
Measure, with a manometer the gas supply pressure (NG: 3.5" ~ 10.5” W.C, LP: 8”~ 13.5" W.C)
2.
Check the Gas meter Capacity.
3.
Tighten the ground connection screws on heat exchanger.
4.
Check if the gas orifice is clogged.
5.
Check if the PCB is working properly.
Does the boiler have
sufficient gas
pressure?
Gas Pressure
Natural Gas: 3.5” - 10.5” W.C.
LP Gas: 8.0" - 13.5" W.C.
Check connector
(#1 of CON22)
see page 56 for Wiring Diagram
Check the gas pressure
NO
YES
* Check the flame detection
AD value for proper resistance.
(refer to page 42~43)
Summary of Contents for NCB-180
Page 3: ......
Page 16: ......
Page 135: ...132 NCB Service Manual Version 1 0 7 2 Burner Assembly...
Page 139: ...136 NCB Service Manual Version 1 0 7 4 Fan Gas Assembly...
Page 142: ...Memo...
Page 143: ...140 NCB Service Manual Version 1 0 Memo...
Page 144: ...Memo...
Page 145: ...142 NCB Service Manual Version 1 0 Memo...
Page 146: ...Memo...
Page 147: ...144 NCB Service Manual Version 1 0 Memo...
Page 148: ...Memo...