Setting the Front Panel DIP Switches
Before change the settings, lift the rubber cover to access the front panel DIP switches.
Set of DIP Switches 1 (Set of 10)
The DIP SW 1 on the front panel configures the temperature ufnit, well pump, and high altitude settings.
SW1 NO.
Application
Setting
Remarks
1
Reserve
2
Temperature
Unit
℃
(Celsius)
2-ON
℉
(Fahrenheit)
2-OFF
3
Well Pump
Well Pump ON
3-ON
Well Pump Mode
These settings are to be used with well system
when an external pump is wired to the boiler.
Well Pump OFF
3-OFF
4 & 5
High Altitude
0-1,999 ft (0-609 m)
4-OFF, 5-OFF
High Altitude
Above 2,000 ft (610 m), the boiler will de-rate
by 4% for each 1,000 ft (305 m) of altitude gain.
This boiler may be installed at elevations up to
10,100 ft (3,078 m) for use with Natural Gas
and 4,500 ft (1,370 m) for use with Propane. To
use the boiler at a specific altitude, the DIP
switches should be set as described above.
2,000-5,399 ft (610-1,645 m)
4-ON, 5-OFF
5,400-7,699 ft (1,646-2,346 m) 4-OFF, 5-ON
7,700-10,100 ft (2,347-3,078
m)
4-ON, 5-ON
6
Reserve
7
Reserve
8
Reserve
9
Reserve
10
Reserve
S/W 2
S/W 1
Summary of Contents for NCB-180
Page 3: ......
Page 16: ......
Page 135: ...132 NCB Service Manual Version 1 0 7 2 Burner Assembly...
Page 139: ...136 NCB Service Manual Version 1 0 7 4 Fan Gas Assembly...
Page 142: ...Memo...
Page 143: ...140 NCB Service Manual Version 1 0 Memo...
Page 144: ...Memo...
Page 145: ...142 NCB Service Manual Version 1 0 Memo...
Page 146: ...Memo...
Page 147: ...144 NCB Service Manual Version 1 0 Memo...
Page 148: ...Memo...