62 NCB Service Manual
Version 1.0
4.9.3 Thermistor
Part
Check Point
Function
Measure Hot water, Cold water, Space heating outlet and inlet temperatures in the boiler.
Failure Event
Unable to properly measure water temperature within the boiler.
Effects
1.
If any of the thermistors fail, an error code appears before starting operation.
2.
If resistance values are off, the boiler will produce temperature fluctuations in hot water.
Error Code
E047, E205, E218, E407, E421
Diagnostic
1.
Visual inspection: Connection and/or breakage of wires.
2.
Check the resistance of the sensor (Stop operating and lower the temperature before checking).
Color/Number of wires
Resistance range : Please refer to the table below
Check if the hot water temperature sensor is open (Error type : MΩ Open)
Temp(°F)
Thermistor (kΩ)
Exhaust Limit Temperature Sensor (kΩ)
32~40
17.9~25.4
113.6~180.7
40~50
14.5~20.3
89.2~139.5
50~60
11.4~16.4
67.5~108.5
60~70
9.4~12.8
51.5~81.1
70~80
7.5~10.4
41.5~61.3
80~90
6~8.2
32.2~48.9
90~100
5.1~6.6
26.3~37.6
Wire Color: BLUE-BLUE
Inlet, Outlet
Exhaust Limit Temperature Sensor
Wire Color: BLUE-BLUE
Summary of Contents for NCB-180
Page 3: ......
Page 16: ......
Page 135: ...132 NCB Service Manual Version 1 0 7 2 Burner Assembly...
Page 139: ...136 NCB Service Manual Version 1 0 7 4 Fan Gas Assembly...
Page 142: ...Memo...
Page 143: ...140 NCB Service Manual Version 1 0 Memo...
Page 144: ...Memo...
Page 145: ...142 NCB Service Manual Version 1 0 Memo...
Page 146: ...Memo...
Page 147: ...144 NCB Service Manual Version 1 0 Memo...
Page 148: ...Memo...