About the Boiler 9
Specifications
Unit
NCB-24LDWE
NCB-28LDWE
NCB-34LDWE
NCB-40LDWE
Flue exhaust/Air intake system types
-
B23-B33-B53-C13-C33-C43-C53-C63-C83
Flue exhaust/Air intake system diameters
mm
Coaxial Ø60/100 and Ø80/125–Dual duct Ø80/80
Max. gas pipe pressure drop
Pa
167
167
294
294
Max. horizontal coaxial length Ø60/100
m
20
Max. vertical coaxial length Ø60/100
m
21
Equivalent elbow length @ 90° Ø60/100
m
1.3
Equivalent elbow length @ 45° Ø60/100
m
1.0
Max. horizontal coaxial length Ø80/125
m
68
Max. vertical coaxial length Ø80/125
m
70
Equivalent elbow length @ 90° Ø80/125
m
2.2
Equivalent elbow length @ 45° Ø80/125
m
1.0
Equivalent length of adapter Ø60/100 => Ø80/125
m
0.5
Max. dual duct length Ø80/80
m
110
Equivalent elbow length @ 90° Ø80
m
2.2
Equivalent elbow length @ 45° Ø80
m
1.4
Hydraulic connection
diameter
Central Heating
mm
22
DHW
mm
15
Gas supply
mm
22
Dimensions (Width x Depth x Height)
mm
440 x 358 x 695
440 x 408 x 695
Total boiler weight (lift weight)
Kg
38
38
42
42
Summary of Contents for NCB-24LDWE