Troubleshooting 71
Error type
Cause
Testing method
Ignition failure
Main gas valve
1. Test the primary and secondary voltages at the main gas valve.
●
Use a multimeter, between the YELLOW - WHITE wires and verify the voltage is
DC 24 V
2. If there is no voltage, replace the PCB.
3. If the voltage is correct, check if the coil is open.
●
Check the resistance. Check if the solenoid valve works correctly.
●
Feel or listen for a click.
Check that the coil is open (Correct resistance range: 100-1,000Ω)
Check the voltage at the solenoid valve / Yellow - White
Summary of Contents for NCB-700-2S+/42K
Page 3: ......
Page 4: ...Revisions 3 Version Description of changes Date 1 00 First issue July 11 2022 Revisions...
Page 119: ...Memo...
Page 120: ...Memo...
Page 121: ...Memo...