Troubleshooting 87
Testing method
Fault
Possible causes
Testing method
E110
Exhaust blockage
Intake air supply /
exhaust flow error
1. If E110 occurs intermittently during ignition or combustion, compare the
standard speed with the current speed at min/max combustion. If the
current speed is higher than normal, check the following:
●
Air supply / exhaust pipes for blockage
●
Blocked condensate drain
●
Broken or blocked air pressure sensor hose
2. Replace the old PCB with the latest version.
Condensate drain error
Condensate drain error
Exhaust air is blocked due to condensate drain faults.
●
Check if the condensate hose or the siphon is frozen.
●
Check if the condensate hose is kinked.
●
Remove the bottom of the trap and verify it is not blocked.
Defective air supply/
exhaust flue
Deformed or blocked flue
1. Check the exterior of the flue for damage and obstructions.
2. Check if rainwater has accumulated in vertically installed sections of the
air intake.
Exhaust gas enters the air
supply pipe
If exhaust gas enters the air supply pipe, combustion faults may cause E110.
●
Check the installation of the flue.