About the Boiler 13
2.5 Dimensions
The following diagrams show the dimensions of the boiler and the table lists the supply connections.
400 mm
680 mm
Supply Connections
Description
Diameter
A
Flue exhaust/Air intake
Ø60/100,
Ø80/125
B
Central heating supply
22 mm
C
Hot water outlet (DHW)
15 mm
D
Gas supply inlet
22 mm
E
Cold water inlet (DHW)
15 mm
F
Central heating return
22 mm
Overhead View
A
197.5 mm
282.5mm
103 mm
Bottom View
E
B
C
D
F
163 mm
163 mm
85 mm85 mm
106 mm106 mm
41 mm
41 mm 75 mm
75 mm 103.7 mm
103.7 mm 94 mm
94 mm
68.2 mm68.2 mm
NCB500-1.5S/37K
NCB500-2S/41K