86 Troubleshooting
5.2.17 Error 421
Error conditions and Check Items
Error
Description
E421
Cold water inlet thermistor open or short
If an error (open: -10°C or lower) in the DHW Outlet Elbow input temperature sensor is
detected, the system displays the 421E error on the front panel.
Check items
1. Check if the cold water temperature sensor connector is wet due to any reason and if
the connector is connected properly.
2. Check if the temperature sensor is open or short.
Is the inlet thermistor
normal?
Check connector
Replace inlet thermistor
See page 38 for Wiring Diagram.
No
Yes
Before measuring resistance of the
thermistor, detach the connector
from the PCB.