| 11
Installation |
Loop S User Manual
F1 F2 F3 F4 F5 F6 F7 F8
R1
R2
R3
R4
R5
R6
R7
R8
F9
F
10
F
11
F
12
F
13
F
14
F
15
F
16
Simplified schematic of the relays and fuses:
F1
R1
1C
4A
F3
R2
1B
4F
F5
R3
1A
4E
F7
R4
3A
4D
F2
R5
1D
3H
F9
R6
1G
3G
+12 V DC
B
C
D
A
F13
R7
1E
4H
F14
R8
1H
2E
F4
4G
F6
4C
F8
4B
F10
2C
F11
2B
F12
2A
F15
2G
F16
2H
E
CAN
F
OUT
. 1
OUT
. 2
OUT
. 3
OUT
. 4
OUT
. 5
OUT
. 6
OUT
. 7
OUT
. 8
OUT
. 9
OUT
. 10
OUT
. 11
OUT
. 12
OUT
. 13
OUT
. 14
OUT
. 15
OUT
. 16
A
Main power input
B
Fuses
C
Relays
D
Override pins for relay outputs
E
Output pins for relays and fuses
F
Output number
¼
Note:
For maximum load and fuse sizes for Output 1 to 8 see Relay and fuse channels in
“Technical Specifications” on page 24.
¼
Note:
For maximum load and fuse sizes for Output 9 to 16 see Fuse channels in “Technical