Data packet is recoreded 

It occurs at the moment of recording the data packet for 
transmission from any source. 

Logic 

Active 
Inactive 

Shock sensor 

It occurs at when the  "the accelerometer sensitivity" value is 
exceeded of in the track settings for transmission via GPRS / 
WiFi communication channels 

Logic 

Active 
Inactive 

Longitudinal tilt 

It occurs at when the "the maximum value of the longitudinal 
tilt" specified in the "Inertial Monitoring" settings is exceeded 

Logic 

Active 
Inactive 

Lateral tilt 

It occurs when the "the maximum value of the lateral tilt" 
specified in the "Inertial Monitoring" settings is exceeded 

Logic 

Active 
Inactive 

Speed in the geofence on the route 

The speed value when going in geofences of the selected 
route. Beyond geofences the value is zero. 

Целочисленное 

 

Output from the dynamic geo-fence 

It occurs at a time of leaving the dynamic geo-fence at the 
same time creating a new one. 

Logic 

Active 
Inactive 

Third-party key 

It occurs if the iButton key is recorded in the memory of the 
device or removable storage (sdCard) 

Logic 

Active 
Inactive 

Battery operation 

It occurs if at the time of the transition to work powered by 
built-in battery in the absence of external power. 

Logic 

Active 
Inactive 

Program timer 1-5 

It occurs: 
1. When the timer value corresponds to the comparison 
function selected for it.  
2. While comparing of the state of running (active)/stopped 
(not active) 

Logic 

Active 
Inactive 
More 
Less 
Equal 
Not equal 
More or equal 
Less or equal 

Program counter 1-12 

It occurs when the counter value corresponds to the 
comparison function selected for it 

Integer-valued 

More 
Less 
Equal 
Not equal 
More or equal 
Less or equal 

Program flag 1-12 

It occurs at the moment of check of the flag state if the 
comparison function has the propper value 

 

Active 
Inactive 

 

Main actions (response to an active event): 

Parameter 

Description 

Taken values 

Operation 

Start events processing 

Perform the actions of any of the created events even if the 
conditions for this event are not fulfilled. ATTENTION! It may 
lead to an infinite cycle. 

Number one of the existing 
events. For the current one the 
specified number is 256. 

Send an extraordinary packet 

Record to buffer for transmission of extraordinary data packet 

Play a voice phrase 

Plays a voice phrase 

The full file name is entered 
manually 

Play an audio file 

Plays the audio file with the specified name. The file must be 
located on the SD card in the directory .. \voice\ 

The full file name is entered 
manually 

 

Wait until the call is answered 

It works in a group with the action "Dial XXX" or "Dial number 
from the list" 

 

 

 

For the convenience of the user, after creating an event, you can go to the emulation mode. In this 

mode, next each condition its current state is specified. When the action is performed, the action being 

performed is specified.  

 

8. CONFIGURATION WIZARD  

The configurator allows you to set the most common configuration used for this wizard in automatic 

mode. After you have completed the settings, the connection diagram for specifically-set configuration is 

displayed. 

To make settings you should go from point to point by entering the required parameters: 

1.

 

 Select the connection parameters - IP address and port of the server, choose the GPRS 

connection provider and the unique device IDD. 

2.

 

To go to the next menu press the "Next" button 

3.

 

2. Selection of the connected peripherals. The setup wizard can automatically configure the 

following connected peripherals: 

4.

 

- FUEL GAUGE - It can be analog, frequency or digital sensor. The necessary interface is installed 

(See Table 4). After selecting the sensor type, choose an input for analog sensors or a port for 

digital ones and network address. If the sensor is configured and connected properly, in the 

current value field a number different from zero will be displayed. After completing the setup 

wizard, the sensor can be calibrated by the calibration wizard. 

 

Summary of Contents for GT-20 LITE

Page 1: ...NAVISET GT 20 PRO IRIDIUM WiFi BT NAVISET GT 20 LITE TRANSPORT MONITORING TERMINALS 2016 Version 5 1 25 01 2016 USER GUIDE Exclusive partner...

Page 2: ...cs SD card support announcement device additional black box Yes No Possible connection of the driver s display Yes No Support of WiFi Bluetooth IRIDIUM GLOBALSTAR Yes No RS232 interface 2pcs 1 piece G...

Page 3: ...speeds up cold start and increases accuracy HANDS FREE is a connection of any tablet PC based on Android to perform the functions of the driver s display loudspeaker communication and access to 3G and...

Page 4: ...of slots for SIM cards SD cards pcs 2 1 2 0 Number of SIM chips pcs optional 2 2 Voice interface for connection of loud speaker communication yes yes Bluetooth interface for the display optional yes n...

Page 5: ...n be replaced by STX3 or Gonets or Inmarsat in software The yellow color indicates the possible combinations of transmitters on the communication channels Combined transmitters can not operate simulta...

Page 6: ...advisable to set GSM as priority transmitter and 5 10 minutes for time of switching and testing of WiFi networks If WiFi appears from time to time it is better to let WiFi remain high priority and to...

Page 7: ...ed only upon request Before ordering it is necessary to agree on prices and date of execution of the order Other versions are available only by special order At the same time the appearance and locati...

Page 8: ...0 to 10 kHz IN4 0 36V analog digital input frequency square signal from 0 to 10 kHz IN5 0 36V analog digital input frequency square signal from 0 to 10 kHz IN6 0 36V analog digital input frequency sq...

Page 9: ...the input and the input 5 Engine hour indicator the input function is designed to count the car engine running time running time of the vehicle and to count the driver s working time When an input vo...

Page 10: ...CATOR Description of modes Is constantly on Data are being transmitted via a satellite Flashes once per second Initialization of the satellite channel Flashes 2 times per second for no longer than 2 s...

Page 11: ...the purpose of the contact See more detailed information in the specification for the handsfree 6 CONTROL AND CHANGE OF SETTINGS USING SMS COMMANDS To control and change the settings via SMS special...

Page 12: ...255 255 12500 After the command is executed the device will be reconnected to the specified address and send an SMS like Remote config 255 255 255 255 12500 COM6 PASS MAP Location information PASS is...

Page 13: ...NUMOP Change the operator in roaming PASS is a current password set in the device Factory default value is 1234 NUMOP an index of the operator of the terminal memory from 1 to 5 EXAMPLE COM17 1234 2...

Page 14: ...a straight section 0 off 1 on DELTA angle of leeway 0 360 MOVETIME record time on the move MINSPEEDANGLE minimum speed of the drawing on turns 0 250 ANGLE angle of the drawing on turns FEVOL filtratio...

Page 15: ...Glonass GPS module WiFi module 5 Software update The configurator is designed to work with NAVISET GT20 GT50 transport monitoring terminals When the configuration device is connected the only paramete...

Page 16: ...mouse over any element in the configurator description of the item and possible actions with is are displayed in this field Create a new configuration with the default parameters Open previously save...

Page 17: ...te connection to the device via GPRS It completely replaces the direct cable connection to the device without restriction of the CONFIGURATOR program functionality To establish the connection click se...

Page 18: ...require a specific APN Information about configuration upload to the cloud See the section of operation with the configurator CLOUD PANEL 7 2 RUNNING THE CONFIGURATOR PROGRAM 7 2 1 STATE MONITORING P...

Page 19: ...onfigured parameters For various modifications the data transmitters assigned to the channel are visually displayed on the panel of communication channels If in the section of Digital ports the satell...

Page 20: ...itter with the mouse up or down In the modification no 4 there is a possibility to choose combination of the IRIDIUM transmitter GlobalStar with the WiFi transmitter on the channel 1 or with GSM on th...

Page 21: ...the stationary mode If within the specified time the motion sensor is inactive the device switches to stationary mode Package recording period while driving specifies the time interval at which data p...

Page 22: ...ot displayed it means either the transmitter is not available or it is faulty IMEI GSM IMEI GSM of a transmitter It is displayed automatically when configuring the local device When the device is remo...

Page 23: ...t it is recommended to make a record according to the distance covered Historical records when parking If the object requires a long parking and at the same time it is necessary to periodically receiv...

Page 24: ...f points recording into memory is the time during which the coordinates are not recorded for any events Minimum number of satellites If the number of visible satellites is less than the specified valu...

Page 25: ...equency Input 1 8 For correct calculation of the frequency set the slider of the lower limit at the level of half the input signal amplitude discrete To connect digital sensors with two work position...

Page 26: ...flag can be processed by events for example dial specific numbers or to send an SMS with the specified text Repeated change to the active state drops the call if dialing of a number or a conversation...

Page 27: ...or flag if the key touches the contactor and removes it if the key is not on the contactor If the checkbox is selected when the key touches the contractor an extraordinary data packet with a key code...

Page 28: ...an choose the port the sensor is connected to in the section SETUP OF CONNECTION TO THE DEVICE and click the Apply button Then you can change the settings of the sensor using the regular software via...

Page 29: ...e In the CLIENT mode the NAVISET device receives data from the external device and records them to the register specified by the user or the external device reads its values from this register In this...

Page 30: ...ue specified by the user After the settings are set and reboot is completed a few parameters will be displayed in the Value column 7 2 7 THE ENERGY SAVING PANEL There are three options for the automat...

Page 31: ...th the announcement of the next stop along the route in other direction the bus stops must be announced in reversed order therefore different voice phrases are used Creating a list of coordinates of g...

Page 32: ...configuration of the device to the cloud service This function is very useful to remotely configure or to set up a large number of devices without a connection to a PC The function is available if the...

Page 33: ...ts that can be interconnected built in the logical chains independently changing static parameters All the logic is based on three main recommended algorithms 1 The linear algorithm as soon as all con...

Page 34: ...e on the battery 0 4 5 Security state Logic Active Inactive Alarm It occurs with the active signal on input with function standard alarm output when the security mode is on Logic Active Inactive Keys...

Page 35: ...ription Taken values Operation Start events processing Perform the actions of any of the created events even if the conditions for this event are not fulfilled ATTENTION It may lead to an infinite cyc...

Page 36: ...itch SW1 see Table 3 to allocate the RS232 interface for this port To check if a video camera is connected properly click PREVIEW If within 10 seconds a video frame appears the camera is connected cor...

Page 37: ...ck the box Run the fuel sensor s calibration wozard 9 FUEL SENSORSCOLEBRATION WIZARD The configurator allows you to make calibration of the fuel sensors connected to device in automatic and manual mod...

Page 38: ...In the table of values the sensor readings corresponding to the amount of fuel poured in the tank will appear Continue to pour fuel intill the tank is completely filled by pressing the Save button aft...

Page 39: ...in the calibration process will indicate how many liters have already been in the tank Specify the input that is connected to the fuel flow meter In the example in the picture the fuel flow meter is c...

Reviews: