Is the concern eliminated?
10
Inspect the circuit integrity for the following:
Ground connections
Connector integrity
Cable routing
Is the circuitry acceptable?
Go to
Step 12
Go to Step
11
11
Repair the circuitry as needed.
Is the concern eliminated?
Concern
resolved
Go to Step
12
12
Consult with Technical Assistance for any
additional available information.
Parts Information
AC-Delco Side Terminal Adapter Package 1846855, when combined with the longer
battery bolt and spacer will provide the simple, light, corrosion-resistant connection
illustrated.
Table 9.1.5: Terminal Adapter Parts
Side Terminal Adapter Package
Description
AC-Delco Catalog 7A10
Car Dealer Parts Book
Kit
1846855
1846855
Bolt
7803
12004188
Spacer
7804
12004189
9. Relocation of electrical Coponents/Devices-Best
Practices/Recommendations
Note: During the upfit process it may, for various reasons, become necessary to remove or
relocate certain electrical connections, components and/or control modules. The following are
the best practices/guidelines as they pertain to these types of components
Safety Systems:
Be advised that the components for the following systems
…Air Bag, Anti
-lock Braking,
Collision Avoidance, Obstacle Detection Lane Departure and Blind Spot Warning cannot be
relocated as the systems are calibrated to their location within and to the vehicle