If you ordered the NAVITAR XENON 560/750DM, the dissolve module
has been attached at the factory. Skip to the section Connecting the
Dissolve Interface to the Dissolve Module.
Make certain the projector is turned off and the power cord is discon-
nected before proceeding.
1. Remove the four (4) white thumbscrews attaching the lamp house
top cover.
2. Remove the top cover and disconnect the white connector.
3. Remove the screws holding the cover plate located on the right
hand side of the main lamp cover (when viewed from the rear).
Once the cover plate on the lamp cover has been removed, you will
see that the lamp cover has been pre-cut to fit over the shutter
blades of the dissolve module.
4. To attach the dissolve module, locate the three (3) pre-drilled holes
located on the right hand side of the projector base (visible when
the lamp cover is removed). Secure the three (3) screws that are
supplied with the dissolve module into the pre-drilled holes. The
shutter blades fit between the flat (plane) mirror and the condenser
lens.
5. Once the dissolve module is secured, connect the white connector,
located behind the plane mirror, to the one supplied with the
dissolve module.
6. Reattach the lamp house cover and replace the four (4) white screws
securing the top cover.
Connect the dissolve interface cords to the corresponding
dissolve
module on the Xenon projector: Cord A to Projector 1, Cord B to
Projector 2 and Cord C to Projector 3. Turn the power switch on the
dissolve interface unit to the ON position.
From time to time, it will be necessary to open the shutter blades of the
dissolve module. The shutter blades may be opened two ways,
manually or automatically.
By opening the door of the dissolve module, you will have access to the
shutter knob. Manually, the shutter blades may be opened by rotating
the shutter knob, assuming the dissolve interface is not connected.
Connecting the
Dissolve Interface to the
Dissolve Module
Attaching a New
Dissolve Module
Units with Dissolve Module & Dissolve Interface