background image

19

EN

Even if the function was not concluded for some reason, there is 

no fear of misuse: when time limit expires, the operation will be 

automatically deactivated.

It is recommended that you add each stored finger to 

the list of administrators and users. If the same fin-

ger of one user is stored more than once, each time it 

should be enrolled separately, because the device re-

cords these as different entries. When deleting a user, 

you need to delete each finger as many times as it was 

saved. On the list you add the user's/administrator's 

name, the date of enrolment, which finger is enrolled 

and how many times. 

3. REMOTE CONTROL 

Enclosed to Bioreader is 1 remote control operating on 433 MhZ 

frequency and communicating with the fingerprint reader over 

encrypted connection with the so called 'rolling code', which 

changes every time when a remote button is pressed. Several 

million different codes are stored in the remote control and 

the reader, and when all are used, they are reused again. The 

codes are interchanged according to a key known only to the 

manufacturer. 

The remote control range is only about 10cm, because the 

fingerprint reader is in metal casing which impedes the signal. 

Remote control has 4 buttons: A, B, C and D. Every button has its 

function; they are described in the following section. 

Remote control and fingerprint reader must be paired. This is 

done in the manufacturing process.. If an additional remote 

control is needed, this can be done according to the procedure 

described below. 

Adding a new remote control: 

On the internal unit, you press the reset button for 10 seconds. 

After 10 seconds, the fingerprint reader starts to emit audible 

signal every second. You have 10 seconds. In this time you have 

to press one of the buttons on remote control, which has to be 

within 10cm from the fingerprint reader. The fingerprint reader 

then emits a short beep and the green LED flashes for 1 second. 

4. CHOOSING THE RELAY 

The device has 2 in-built output relays, so that with one finger-

print reader you can open two doors or a door and another de-

vice of your choice (e.g. an alarm). When you store a fingerprint 

you should also choose a relay which will be triggered by this 

fingerprint. You do that when you add a fingerprint to the data-

base, so that you press an adequate button on remote control 

for 2s. If you press button A, relay #1 will be triggered, if you 

press button B, relay #2 will be triggered, and if you press button 

C, both relays will trigger simultaneously.

5. ADMINISTRATOR’S ROLE AND ADMINISTRATOR ENROLLMENT 

Only an administrator can enrol and delete other users. The first 

three stored fingerprints are entitled to administrator rights. 

These can be the fingerprints of one, two or three individuals. 

Carefully consider which finger you will choose for the 

administrator finger. It should be without injuries and 

have a prominent fingerprint. Do not enrol this finger 

as a user finger later on, because this can result in prob-

lems with managing! 

Administrator enrolment procedure: 

• 

Press button A for 3s. The white LED will start to flash quickly. 

• 

By pressing a button you choose which relay will be triggered 

by the finger you are adding (button A, B or C). The green LED 

f a 1s beep is heard, the white LED starts to flash slowly. 

• 

Administrator then presses the finger he/she is enrolling on 

the fingerprint reader for 7-10 seconds or until the green LED 

f a 1s beep is heard. 

• 

If enrolment is unsuccessful, the red LED f three 1s 

beeps are heard and the procedure has to be repeated. 

• 

When the administrator is correctly enrolled, the green LED 

f a 1s beep is heard. Repeat the same process with the 

remaining two administrator fingerprints. 

IMPORTANT: 

Administrator fingers can be deleted only when the entire 

database is deleted. Therefore you should carefully consid-

er who will be assigned with administrative rights, especial-

ly if the device will be used by several people. 

6. USER FINGER ENROLMENT

After all administrators are enrolled, pressing button A for 3 

seconds triggers the 'enrol user finger' function. The user’s only 

right is unlocking the door; a user cannot trigger any other 

function. 

User finger enrolment procedure

• 

Press button A for 3s. The white LED starts to flash slowly. 

• 

The administrator presses his/her finger on the fingerprint 

reader to confirm the beginning of enrolment of a user. After 

positive identification of the administrator fingerprint, the 

green LED f a 1s beep is heard, the white LED starts to 

flash quickly. 

• 

By pressing a button you choose which relay will be triggered 

by the finger you are adding (button A, B or C). The green LED 

f a 1s beep is heard, the white and green LED start to 

flash alternately. 

• 

The user now lays the finger he/she enrols on the fingerprint 

reader for 7-10 seconds or until the green LED f a 1s 

Summary of Contents for Bioreader

Page 1: ...USER MANUAL...

Page 2: ...g User interface a 3 colour LED a beeper a remote control Attached is a 2m cable to connect the fingerprint reader and the relay unit TABLE OF CONTENTS 1 THE FIRST STARTUP 18 2 PROPER USE 18 3 REMOTE...

Page 3: ...for 7 10 seconds After successful enrolment the device beeps and the green LED flashes for 1 second It is recommended that you enrol the same finger several times so that different positions of a fing...

Page 4: ...ol for 2s If you press button A relay 1 will be triggered if you press button B relay 2 will be triggered and if you press button C both relays will trigger simultaneously 5 ADMINISTRATOR S ROLE AND A...

Page 5: ...administrator The procedure of deleting all fingerprints from the database Press button C for 3s The white and red LED start to flash al ternately The administrator presses his her finger on the fing...

Page 6: ...not identified The fingerprint was not stored in the database Timeout of a function Red Yes On 3 s Fingerprint database is full Green white No Flashing alternately Until timeout Bioreader is waiting...

Page 7: ...ds a fault in the functioning of the product they can enforce the rights under the warranty on the seller or the manufacturer who shall issue a claim receipt The manufacturer undertakes that in the ev...

Page 8: ...month and day of purchase name of the customer or seller and serial number 8 When the warranty certificate is not accompanied by the re ceipt for the item s purchased invoice Limits of liability Navk...

Reviews: