1 Installation and Troubleshooting Guide
26
Active Low Input Configuration
When configured as an Active Low Input, the input state is considered ON when it becomes low.
The voltage thresholds that trigger the change in input state are as follows:
1.10.2 Digital Outputs DO-1 & DO-2
The Digital Outputs will pull to Ground and sink a maximum current of 250 mA when activated.
The outputs have over-current trip protection and, if tripped, the output must be changed to
OFF or have a power cycle to reset the current trip.