** The standard ACB in the catalog comes with D0, D0, U0, AX, and B
options.
Sunt Coil
D0 Without Shunt coil
D1 AC/DC 100V~130V
D2 AC/DC 200V~250V
D3 DC 125V
D4 DC 24V~30V
D5 DC 48V~60V
D6 AC 380V~480V
D7 AC 48V
Closing coil
D0 Without Closing coil
D1 AC/DC 100V~130V
D2 AC/DC 200V~250V
D3 DC 125V
D4 DC 24V~30V
D5 DC 48V~60V
D6 AC 380V~480V
D7 AC 48V
UVT Coil
U0 Without UVT coil
U1 AC/DC 100V~130V
U2 AC/DC 200V~250V
U3 DC 125V
U4 DC 24V~30V
U5 DC 48V~60V
U6 AC 380V~480V
U7 AC 48V
Aux. contact & charging types
AX Standard OFF-Charge 3a3b
AC Standard ON-Charge 3a3b
BX Standard OFF-Charge 5a5b
BC Standard ON-Charge 5a5b
HX High capacity OFF-Charge 5a5b
HC High capacity ON-Charge 5a5b
CC Standard ON-Charge 6a6b
JC High capacity ON-Charge 6a6b
GX High capacity OFF-Charge 3a3b
GC High capacity ON-Charge 3a3b
TX TCS OFF-Charge 4a4b
TC TCS ON-Charge 5a5b
AL Option
AL Option
AL AL1+MRB
B B On/Off Button lock
A1 AL1+MRB+RES (AC110~130V)
M MI Mechanical interlock
A2 AL1+AL2+MRB
D Door Interlock or MOC
A3 AL1+MRB+RES (DC110~125V)
K K1 Keylock
A4 AL1+MRB+RES (AC200~250V)
K2 K2 Key Interlock set
A5 AL1+MRB+Auto reset
K3 K3 Key lock double
A6 AL1+AL2+MRB+Auto reset
R RCS Ready to close switch
A7 AL1+MRB+RES (DC110~125V)+Auto reset
T TM Temperature monitoring
A8 AL1+MRB+RES (AC200~250V)+Auto reset
H1 AC/DC 100~130V
A9 AL1+MRB+RES (AC110~130V)+Auto reset
H2 AC/DC 200~250V
Y2 AL1+AL2+MRB (2b contact)
H3 DC 125V
Y6 AL1+AL2+MRB+Auto reset (2b contact)
H4 DC 24~30V
Z2 AL1+AL2+MRB (1a1b contact)
H5 DC 48~60V
Z6 AL1+AL2+MRB+Auto reset (1a1b contact)
H6 AC 380~480V
C C Counter
H7 AC 48V
S CS2 Charge switch communication
Catalogue number:
AN
□□□□□□
AS
Air Circuit Breaker 1600-5000 70-85kA
AS
□□□□□□
Optional Configuration
* AL- Trip Alarm
MRB- Manual Reset Button
RES- Remote reset switch
MOC- Mechanically Operated cell
Switch
** Only 1 alarm trips options can be
installed.
Only 1 key lock options can be
installed.
Only 1 double shunt to be installed,
and it cannot be used simultaneously
with UVT.
MI cannot be used simultaneously
with DI or MOC.
RCS and CS2 cannot be used
simultaneously.
N.A.W. Controls Pty. Ltd.
Telephone: (03) 9464 6555
www.nawcontrols.com.au
LS ACB AS & AN range
June 2020
Trip Unit Configuration
AG5
- Protection: Long time, Short time, Instantaneous, ground fault and
thermal.
- Measurement of current on each phase.
- Fault alarm for long time, short time, Instantaneous and ground faults.
- Communication: Modbus/RS-485
Profibus- DP
- Power supply: self-power, work over 20% of the load current. (External
power source required for comms).
-AC/DC 100~250V
-DC 24~60V
- 10 fault recording stored
- Operating buttons: Reset, Menu