Gas - Meritus GB – Gas Range Series
FRM-PDE-03-04
Open Burner
Type
Gas
Type
Nozzle D
max
P (mbar)
By-pass
Screw
Primary Air
H (mm)
Pilot
Nozzle Ø
(
)
3.5 kW
(D Type)
G30/G31 Ø 0.90
28-30/37 Ø 0.60
Full Open
Ø 0.25
Ø0.80
50/50
Ø 0.50
Full Open
Ø 0.25
G20
Ø 1.50
20
Adjusted 1
Ø 0.35
25
G25
Ø 1.60
20
Adjusted
1
Ø 0.35
Ø 0.15
25
Adjusted
1
Ø 0.35
G25.1
25
Open Burner
Type
Gas Type Nozzle D
max
P (mbar) By-pass
Screw
Primary Air
H (mm)
Pilot Nozzle
Ø (mm)
5.5 kW
(D Type)
G30/G31 Ø 1.15
28-30/37 Ø 0.60
Full Open
Ø 0.25
Ø 1.10
50/50
Ø 0.50
Full Open
Ø 0.25
G20
Ø 1.85
20
Adjusted 2
Ø 0.35
25
G25
Ø 2.00
20
Adjusted
2
Ø 0.35
Ø 1.90
25
Adjusted
2
Ø 0.35
G25.1
25
Open Burner
Type
Gas Type
Nozzle D
max
P (mbar)
By-pass
Screw
Primary Air
H (mm)
Pilot Nozzle
Ø (mm)
7.5 kW
(E Type)
G30/G31 Ø 1.35
28-30/37 Ø 0.60
Full Open
Ø 0.25
Ø 1.30
50/50
Ø 0.50
Full Open
Ø 0.25
G20
Ø 2.15
20
Adjusted 1.5
Ø 0.35
25
G25
Ø 2.35
20
Adjusted
1.5
Ø 0.35
Ø 2.25
25
Adjusted
1.5
Ø 0.35
G25.1
25
Open Burner
Type
Gas
Type
Nozzle D
max
P (mbar) By-pass
Screw
Primary Air
H (mm)
Pilot Nozzle
Ø (mm)
10 kW
(F Type)
G30/G31 Ø 1.50
28-30/37 Adjusted
Full Open
Ø 0.25
Ø 1.35
50/50
Adjusted
Full Open
Ø 0.25
G20
Ø 2.35
20
Adjusted 2.5
Ø 0.35
25
G25
Ø 2.60
20
Adjusted
2.5
Ø 0.35
Ø 2.45
25
Adjusted
2.5
Ø 0.35
G25.1
25
Table 11
NAYATI
30
20151125
Summary of Contents for NGR 8-75
Page 14: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGR 12 75 MR Fig 5 NAYATI 14 20151125...
Page 15: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGTR 4 75 MR Fig 6 NAYATI 15 20151125...
Page 16: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGTR 8 75 MR Fig 7 NAYATI 16 20151125...
Page 17: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGTR 12 75 MR Fig 8 NAYATI 17 20151125...
Page 38: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 CE Certificate CE Certificate NAYATI 38 20151125...