background image

GEN4065 4000 Surge Watts/3250 Running Watts Portable Generator  

6  

 

                                                                      

 

Powerful Voltage:

 This generator produces powerful voltage, which can result in electrocution. 

• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual). 
• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical 

system to this generator without a qualified electrician. Such connections must isolate generator power from utility power and comply with local 

electrical laws and codes. Failure to comply can create a back feed into utility lines creating an electrocution hazard, which may result in serious 

injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create fires when utility power is restored. 
• Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. GFCIs are available in-line with 

some extension cords. 

• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep this generator dry and operate 

it with dry hands. 
• Do not touch bare wires or outlets (receptacles). 

• Do not allow children or non-qualified persons to operate this generator. 
  

                                                                      

 

High Temperatures:

 This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees 

Fahrenheit (65 Degrees Celsius). 

• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces. 
• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that are hot during operation and 

before storing indoors. 

• Hot exhaust may ignite some materials. Keep flammable materials away from this generator. 

• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this generator in any structure. 
 
                                                                      

 

Usage:

 Misuse of this generator can damage it or shorten its life. 

• Use this generator only for its intended purpose. 

• Operate this generator only on a dry, level surface. Do not secure the generator with a chain or rope, which would prevent it from being moved 

in an emergency. 
• Allow this generator to run for several minutes before connecting any electrical devices. 

• Promptly turn off any malfunctioning devices and disconnect them. 

• Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator. 

• Do not turn on electrical devices until after they are connected to this generator. 
• Turn off all connected electrical devices before stopping this generator. 
 

                                                                                 

 

Usage:

 Consult a physician(s) before using this generator if using a pacemaker. Electromagnetic fields in close proximity to a heart 

pacemaker could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine’s recoil starter. 
 
                                                                               

 

Usage:

 Prolonged exposure to high noise levels can be hazardous to hearing. Always wear ANSI-approved hearing protection when 

operating or working around the generator when it is running. 
 

                                                                               

 

Usage:

 This generator is not intended to power sensitive electronic equipment such as TVs, DVD players, stereos, desktop 

computers or laptop computers without the use of an appropriate line conditioner and/or surge protector (both not included). 
Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators. For additional 

information consult the devices operation manual or call customer service  at 1-866-460-9436 Monday - Friday, 8 AM - 4 PM Central Time. 
 

                                                                                 

 

Usage:

 Avoid the use of extension cords if possible. If you choose to use them, be sure they are sized adequately to handle the flow of 

electricity. An undersized cord can overheat, short out and cause a fire. 
 

Meijer.com

Summary of Contents for GEN4065

Page 1: ...that may occur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN TH...

Page 2: ...ts 3250 Running Watts Portable Generator FEATURES 4 Stroke OHV Engine Recoil Start 6 5 HP Gasoline Engine Automatic Low Oil Shutdown 2 120 Volt A C Outlets 1 12 Volt D C Outlet 4 Gallon Fuel Tank Engi...

Page 3: ...contiguous states excluding the states with high altitude areas identified in 40 CFR part 1068 Appendix III To exercise this warranty DO NOT RETURN TO RETAILER Instead call Customer Service toll free...

Page 4: ...ons you do not understand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or deat...

Page 5: ...SECURE THE GENERATOR WITH A CHAIN OR ROPE AS THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY Keep at least several feet of clearance on all sides to allow proper ventilation for this generator Che...

Page 6: ...least several feet of clearance on all sides of this generator during operation Do not enclose this generator in any structure Usage Misuse of this generator can damage it or shorten its life Use this...

Page 7: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 7 Meijer com...

Page 8: ...65 4000 Surge Watts 3250 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator Meijer...

Page 9: ...able Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETA...

Page 10: ...nd controls of this generator 9 AC Circuit Fuse 10 AC Circuit Fuse 11 120 Volt AC Output Socket 12 120 Volt AC Output Socket 13 12 Volt DC Output Socket 14 DC Circuit Fuse 1 Fuel Tank Cap 2 Control Pa...

Page 11: ...nkcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 20 fluid oz 0 59 L for this Model GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator Add the...

Page 12: ...ecause gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN4065 Fuel Tank Capacity...

Page 13: ...vel currently in the fuel tank If necessary add fresh unleaded gasoline with an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of...

Page 14: ...sized cord can overheat short out and cause a fire Usage Do not use fuel stabilizers with this generator doing so could cause damage to the generator or decrease the fuel and operating efficiency of t...

Page 15: ...total wattage of the selected devices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less t...

Page 16: ...lt outlet Connect 12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 4000 do not attempt to draw more than 3500 Watts from the 120 Volt outlet Draws high...

Page 17: ...enerator Failing to use the correct procedure can cause a battery to explode seriously injuring anyone nearby Keep heat sparks flame and smoking materials away from the battery To connect 12 Volt batt...

Page 18: ...ocedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep heat...

Page 19: ...ery 100 hours of use time The oil capacity for this Model GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator engine is 20 fluid oz 0 6 L To drain the oil from this generator It is necessar...

Page 20: ...and install a new spark plug A F6TC spark plug such as NGK BPR5ES is recommended 4 Measure the spark plug electrode gap with a gauge The gap should be 0 028 0 031in 0 7 0 8mm See Figure 9 5 If re usin...

Page 21: ...trouble persists call our customer help line at 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time Symptom Cause Solution Engine switch is set to off Set engine switch to on Fuel valve is turned to c...

Page 22: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 22 GEN4065 4000 SURGE WATTS 3250 RUNNING WATTS PORTABLE GENERATOR PARTS DIAGRAM Meijer com...

Page 23: ...som 2 17 Bolt GB T5789 M6 12 8 18 Tank Cock 1 19 Fuel Pipe 1 20 Muffler Guard Cover 1 21 Bolt GB T5789 M6 16 2 22 Muffler 1 23 Bolt GB T16674 M8 20 3 24 Muffler Bracket 1 25 Nut GB T6184 M8 12 26 Engi...

Page 24: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 24 GEN4065 2011 08 Meijer com...

Reviews: