background image

3. RECEIVER

Compact-V

Mounting possibility of the receiver

Compact-V.

.

WRONG

Mounting on a tower slewing crane.

Top slewing crane: Mount the antenna with
extension cable horizontally.

RIGHT

The receiver is connected to the unit to be controlled with the multi-pin connecting
cable supplied. Please observe the instructions issued by the manufacturer of the unit

to be controlled!

The power supply of the receiver is generally effected by the connecting cable.

We recommend urgently to realize this connection via a central, well

accessible, multi-pin plug connector (for example HTS-plug connector series

HE/HB/HN/HA or comparable ones of other manufacturers) to make possible a quick
and clear fault diagnosis in the service case and to take off the receiver without an

expenditure of assembly.

In general, an earth lead is required in case the units to be controlled have not pre-

viously been operated by radio control. Failing this, the

receiver electronic circuit will not receive any power supply. Ensure that the opera-

ting voltage of the receiver

complies with the electrical specifications of

the unit to be controlled. The applicable operating voltage is specified in the supp-

lement.
Never expose the receiver to a high pressure cleaning jet. This applies to the

transmitter also.
The receiver should always be fixed vertically at the outside panel of the swit-

ching cabinet. (The antenna should always reach over the top of the panel.)
You have to make sure that the antenna is not shielded by metal parts totally or part-

ly.
Mounting the receiver in a cabine or in a switching cabinet the antenna should be

layed with an extension cable to the outside and be attached with the fastening

strapping as horizontally as possible with distance to the shielding metal parts.
In general the antenna should always be mounted in such a way so that the antenna

is still visible with each change of position of the transmitter.

%

%

%

%

%

%

WRONG

RIGHT

Compact-V

Reviews: