16
4 Installation and Connection
■If installing the unit using the adapter plate (optional)
An adapter plate is used when replacing digital position indicators
with sizes as per Fig. 1 or Fig. 2. When shipped, the position of the
adapter plate positioning pin is matched for sizes of Fig. 2. Rotate
the positioning pin anti-clockwise with a flathead screwdriver and
remove it when replacing digital position indicators with sizes as per
Fig. 1, then change its position. (Recommended tightening torque:
0.3 N・m)
22
Φ6
max.
Φ
20
Diagram 1
max.
Φ
20
30
Φ6
Diagram 2
30
22
Positioning pin