2  

NC Spinner Speed Monitor  

NC-015103C Ver 2 

Description 

The Rev-counter is powered by an internal 3.0 V lithium battery 
The sealed front panel meets NEMA 4X/IP65 specifications for wash-down and/

 

or dusty environments when properly installed. 

©

2010 Newton Crouch Inc.  Rev 8.19.10 This information is the property of Newton Crouch Inc. and is loaned confidentially to our customer for his sole use.  It must not be used in any way 

detrimental to our interest or shared with outside parties.    O:\Production\Technical Tips\SSM NC-015103C 

Specifications 

DISPLAY:   5-digit LCD, 0.6” (15.2mm) high digits 
POWER SOURCE:   Internal 3.0 V lithium battery to provide up to 7 years of con-

 

tinuous service (battery life is dependent upon usage.) 

OPERATING TEMPERATURE RANGE:   0° C  to 75° C  or  32° F to 167° F 
STORAGE TEMPERATURE RANGE:   -30° C to  80° C  or   22° F to 176° F 

Electrical Connections 

Since the Rev-counter is self powered, only 2 electrical connections are re-

 

quired.  These connections are made utilizing 2 of the 3 terminal blocks,      

 

located at the rear of the unit.  Refer to the procedures below when connecting 

 

the Rev-counter to the Pickup. 

Connect the BARE and the WHITE wire to the #1 GND terminal. 
Connect the BLACK wire to the #3 INP terminal. 

Installation 

The Rev-counter  should be mounted so that it can be seen by the operator of 

 

the spreader while spreading is taking place. 

The sensor should be as close to the timing disc as possible without rubbing—  up to 

 

¼

” away.  If sensor is too close, it will read all the time. 

Switches are set correctly by Newton Crouch Inc.  The correct positions are  indi-

 

cated by the diagram below. 

Drawing 1 