3-72
Chapter 3: Setup
1RWH
Serial ports 3 and 4 (COM C and COM D in the BIOS) will not
operate correctly when running Windows 2000 and NT 4.0. To resolve
any conflicts, one of the following configuration changes could be
made depending on individual configurations:
1) Enable COM3 and configure it to use IRQ 5.
2) Disable the Floppy Drive if not used, then enable COM3 and
configure it to use IRQ 6.
3) Disable the Parallel Port if not used, then enable COM3 and
configure it to use IRQ 7.
1RWH
The Mouse uses IRQ 12 and so does the Touch Screen. Since the
Touch Screen serves as a mouse, it cannot be freed up unless you don't
want to use either. The Audio and LAN share IRQ 10, and since these
are PCI IRQs, they can move around depending on what is available in
the system.