NCR RealPOS 25 Terminal Site Preparation
Electrical Requirements
7610 Terminal Power Requirements
The terminal's external power supply has a maximum output of 150 Watts and provides
power to the terminal and its powered peripherals.
Range
Nominal
Vrms
Minimum
Vrms
Maximum Vrms
Input Current Max.
Arms
LOW (115)
100-127
90
136
2.2A
HIGH (230)
200-240
180
265
1.2A
Caution:
Locate the power supply away from other electrical equipment, away from
heat sources, away from possible liquid spills, and where there is adequate clearance for
cooling.
Note:
The RealPOS 25 does not offer an AC convenience outlet for CRT power. A
separate country-specific power cord must be ordered separately. Available NCR power
cords are described in the
System Cables
section.
Peripheral Power Requirements
The number of peripherals that the terminal can support is dependent upon which
peripherals are connected. For planning purposes, use the
RealPOS 25 (7610) Release 1.0
Power Matrix
(B005-0000-2021) for details on total power distribution.
Note:
This file requires Microsoft Excel to run.
AC Store Wiring Requirements
The customer must provide suitable AC power for the terminals, associated equipment,
and devices. We recommend a dedicated unswitched power line dedicated to the NCR
equipment installation. Refer to the
NCR Workstation and Peripherals AC Wiring Guide
(BSTO-2115-53) for store AC wiring requirements. The AC outlet must be installed near
the terminal and easily accessible to the operator.
Summary of Contents for RealPOS 25
Page 1: ...SITE PREPARATION GUIDE NCR RealPOS 25 7610 POS Release 2 0 B005 0000 2018 Issue C...
Page 11: ...NCR RealPOS 25 Terminal Site Preparation 5 Dimensions Terminal w MSR...
Page 16: ...10 NCR RealPOS 25 Terminal Site Preparation NCR 5976 2x20 LCD Dimensions...
Page 19: ...NCR RealPOS 25 Terminal Site Preparation 13 Power Supply Dimensions Power Supply Bracket...
Page 34: ...28...