Chapter 5: Programming
5-7
Programming Mode
To program your RealScan 7892, it must be in the Programming Mode.
Enter this mode by scanning the Programming Mode tag immediately
after applying power to the scanner; it must be the first tag scanned.
This puts the scanner in the Base Programming state. When entering
the Base Programming state, the scanner produces a long then short
beep; the Status Indicator stays off.
From the Base Programming state, select specific programming modes
by scanning the proper two hexadecimal tags. The program parameters
that you enter in a specific programming mode are identified on the
associated Programming Worksheet.
In each specific programming mode, enter all the information
contained on the worksheet by scanning all the proper tags in sequence
as shown on the worksheet. In addition, use parameter shortcuts to
enter a specific parameter. Program entry goes directly to a specific
parameter when you scan the proper Hex tag.
If you do not know how your RealScan 7892 is programmed, you can
set it to all defaults, then enter any required changes to match your
program. Do this by scanning the Default tag as the first tag after
applying power to the scanner. This sets the defaults for the
programmed default setting in the scanner. Next, scan the
Programming Mode
tag to enter the Programming Mode.
The scanner accepts programming tags only in the Programming
Mode. If you scan a programming tag during normal operation,
nothing happens.