Console Redirection
2-8
MP-RAS Remote Support
Enabling Console Redirection with BIOS Setup
The following table defines the BIOS Setup Utility options that must be
configured to enable console redirection.
Menu
Options
Comments
Peripheral
Configuration
Serial Port 1 Address
or
Serial Port 2 Address
Both COM1 and COM2 are
available for general purpose
use.
If remote management and
console redirection support are
required, you must enable
either COM1 or COM2 for
these purposes.
UNIX MP-RAS only uses
COM1 for console redirection.
Console Redirection
Select Port 1 to redirect the
console to COM1 or Port 2 to
redirect the console to COM2.
Serial Port Baud Rate
Enter the baud rate for the
remote support modem. Your
choices are: 9600, 19.2 K, 38.4
K, or 115.2 K.
115.2K baud rate is not
recommended. The Diagnostic
Partition does not support file
downloads (via the rf utility) at
115.2K baud.
UNIX MP-RAS does not
support
115.2 K baud rate for remote
console, either via modem or
direct connect terminal.
Redirection Flow Control
Enter the type of flow control to
be used. Always set this option
to “CTS/RTS & CD” flow
control.
Summary of Contents for S46
Page 1: ...B003 0145 A 6 97 NCR S46 Server MP RAS Support Guide Release 1...
Page 6: ...Contents iv Contents...
Page 10: ...Preface viii Preface...
Page 11: ...NCR S46 Server MP RAS Support Guide 1 1 Chapter 1 Installing MP RAS...
Page 32: ...Restoring MP RAS 1 22 Installing MP RAS...
Page 33: ...NCR S46 Server MP RAS Support Guide 2 1 Chapter 2 MP RAS Remote Support...
Page 88: ...Using the Server Monitor Module for Remote Management 2 56 MP RAS Remote Support...