background image

NCR

 

Proprietary

 

Information

 ‐ 

not

 

to

 

be

 

disclosed

 

or

 

reproduced

 

without

 

written

 

consent.

 

©

 

2017,

 

2018

 

by

 

NCR

 

Corporation,

 

Atlanta,

 

Georgia,

 

U.S.A.

 

http://www.ncr.com.All

 

Rights

 

Reserved

B006

7519

G000

Variant

 

Details

 ‐ 

CEN

 

I,

 

Standard

 

Collar

 

ATM

 

NCR

 

SelfServ™

 

84

 

Walk

Up

 

ATM

 

Site

 

Preparation

9

 ‐ 

3

SECURITY

 

BOLTS

Bolts

 

and

 

anchors

 

must

 

be

 

supplied

 

by

 

the

 

owning

 

organisation.

To

 

meet

 

security

 

standards

 

the

 

ATM

 

must

 

be

 

bolted

 

to

 

the

 

floor,

 

through

 

all

 

of

 

the

 

bolt

 

holes,

 

using

 

bolts

 

with

 

anchor

 

washers

 

as

 

specified

 

below.

 

Bolts

 

and

 

anchor

 

washers

 

are

 

to

 

be

 

supplied

 

by

 

the

 

owning

 

organisation.

Make

 

sure

 

that

 

the

 

floor

 

or

 

plinth

 

is

 

capable

 

of

 

withstanding

 

the

 

loading

 

imposed

 

by

 

the

 

anchor

 

points

 

for

 

these

 

bolts.

If

 

an

 

adjustable

 

plinth

 

is

 

used,

 

it

 

must

 

be

 

bolted

 

to

 

the

 

floor

 

to

 

the

 

same

 

specification

 

as

 

the

 

ATM.

The

 

minimum

 

specification

 

for

 

bolts

 

and

 

washers

 

to

 

secure

 

the

 

ATM

 

to

 

a

 

concrete

 

floor

 

is:

Bolts

Type

 ‐ 

either

 

resin

 

anchor

 

or

 

shield

 

anchor

 

bolts

Size

 ‐ 

M16

 

(5/8

 

in.)

Minimum

 

Length

 ‐ 

150

 

mm

 

(5.9

 

in.)

Strength

 ‐ 

high

 

tensile

 

(minimum

 

ISO

 

property

 

class

 

8,8

).

Washers

Type

 ‐ 

flat,

 

steel

 

(as

 

per

 

DIN7349

 

or

 

equivalent)

Size

 ‐ 

M16

 

(5/8

 

in.)

Outer

 

diameter

 ‐ 

no

 

greater

 

than

 

40

 

mm

 

(1.58

 

in.)

Minimum

 

thickness

 ‐ 

6

 

mm

 

(0.2

 

in.).

BOLT

 

HOLES

The

 

ATM

 

should

 

be

 

bolted

 

to

 

the

 

floor

 

or

 

plinth,

 

through

 

all

 

the

 

holes

 

marked

 

‘A’,

 

using

 

four

 

bolts

 

with

 

anchor

 

washers.

The

 

hole

 

marked

 

‘B’

 

enables

 

an

 

alarm

 

to

 

be

 

fitted.

Short

 

Sleeve

Long

 

Sleeve

B

A

A

A

A

Hole in Wall

203 mm

(7.99 in.)

Maximum

390 mm

(15.35 in.)

500 mm

(19.68 in.)

250 mm

(9.84 in.)

284.5 mm

(11.20 in.)

770 mm

(30.31 in.)

169.5 mm

(6.67 in.)

800 mm

(31.50 in.)

164 mm

(6.46 in.)

500 mm

(19.68 in.)

250 mm

(9.84 in.)

136 mm

(5.35 in.)

18 mm

(0.70 in.)

100.5 mm

(3.96 in.)

Hole A Bolt Holes

Hole B (Alarm Hole)

40 mm

(1.57 in.)

40 mm

(1.57 in.)

21 mm

(0.83 in.)

25 mm

(0.98 in.)

28 mm

(1.10 in.)

65 mm

(2.56 in.)

45 mm

(1.77 in.)

28 mm

(1.10 in.)

B

A

A

A

A

Hole A Bolt Holes

Hole B (Alarm Hole)

330 mm

(12.99 in.)

Maximum

504 mm

(19.84 in.)

Hole in Wall

500 mm

(19.68 in.)

250 mm

(9.84 in.)

284.5 mm

(11.20 in.)

770 mm

(30.31 in.)

169.5 mm

(6.67 in.)

800 mm

(31.50 in.)

164 mm

(6.46 in.)

500 mm

(19.68 in.)

250 mm

(9.84 in.)

136 mm

(5.35 in.)

18 mm

(0.70 in.)

100.5 mm

(3.96 in.)

40 mm

(1.57 in.)

40 mm

(1.57 in.)

21 mm

(0.83 in.)

25 mm

(0.98 in.)

28 mm

(1.10 in.)

65 mm

(2.56 in.)

45 mm

(1.77 in.)

28 mm

(1.10 in.)

Summary of Contents for SelfServ 84 Walk-Up

Page 1: ...NCR SelfServ 84 Walk Up Standard Collar ATM Site Preparation B006 7519 G000...

Page 2: ...NCR s copyright notice must be included It is the policy of NCR Corporation NCR to improve products as new technology components software and firmware become available NCR therefore reserves the right...

Page 3: ...onths 5 2 Transit Range Up To One Week 5 2 Extreme Power On Range Up To One Hour 5 2 Barometric Pressure 5 2 Power Requirements AC Power Requirements 6 1 Input Voltage Setting 6 1 Grounding 6 1 Transi...

Page 4: ...h page has two or three columns laid out as follows Where left and right side are stated the ATM is viewed from the front facia side of the ATM All plan views are from the top unless otherwise stated...

Page 5: ...The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer For information and guidance purposes only a list is provided in general terms of...

Page 6: ...ds The ATM complies with the following requirements for radiated and conducted immunity EN 55024 1998 A1 2001 A2 2003 As per the requirements of EN55024 the ATM complies with the requirements of the f...

Page 7: ...e with a medium to high feature functionality configuration Heat dissipation figures are largely unaffected by transactional rates PRODUCT IDENTIFICATION The illustration below is typical of the layou...

Page 8: ...M can be found in the Variant Details sections DOORWAYS AND CORRIDORS Make sure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through o...

Page 9: ...d humidity to a maximum humidity at 0 C 32 F Normal Operating Range Interior Environment Temperature 0 C to 40 C 32 F to 104 F Relative Humidity 20 to 80 Dew Point Temperature Restriction 26 C 79 F ma...

Page 10: ...termittent short circuits and switching transients can be introduced on to power lines Such transient energy can be very damaging to electronic hardware and can also cause data corruption Under these...

Page 11: ...ne of two options a basic alarm system or an enhanced alarm system A stabilised non interruptible power supply must be provided through the external alarm system The alarm interface cable wiring must...

Page 12: ...rm to the following specification and wiring Remove a 20 mm 0 79 in section of the outer sleeve 100 mm 3 94 in from the ATM end of the cable Take care not to cut through the cable shielding ETHERNET S...

Page 13: ...rif typeface should be used Tiresias is recommended The text size should be at least 14 point and larger where possible Where tactile decals are required they should be designed in line with specific...

Page 14: ...7 in 770 mm 30 31 in 832 mm 32 76 in 664 mm 26 14 in 800 mm 31 50 in 801 mm 31 54 in 259 mm 10 20 in 226 mm 8 90 in 66 mm 2 60 in Note 1 60 mm 2 36 in 681 mm 26 81 in 502 mm 19 76 in 62 mm 2 44 in Not...

Page 15: ...7 in 165 mm 6 50 in Contactless Card Reader behind Facia 915 mm 36 02 in 1033 mm 40 67 in 165 mm 6 50 in PIN Pad Number 5 Key 849 mm 33 43 in 967 mm 38 07 in 136 5 mm 5 37 in Private Audio 780 mm 30 7...

Page 16: ...high tensile minimum ISO property class 8 8 Washers Type flat steel as per DIN7349 or equivalent Size M16 5 8 in Outer diameter no greater than 40 mm 1 58 in Minimum thickness 6 mm 0 2 in BOLT HOLES T...

Page 17: ...mum 12 99 in 203 mm 330 mm 534 mm 21 02 in B 18 mm 0 71 in 625 mm 24 61 in A Hole in Wall ATM Base View from Inside Building Plinth Sidewalk increase to 635 mm 25 00 in if ATM installed with cash came...

Page 18: ...hown assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging A surrounding clearance of 6 mm 0 24 in has been allowed in the dimensions 47 mm 1 85 in 31 5 mm 1 2...

Page 19: ...Minimum However note that installing the ATM in the minimum servicing area may increase the servicing and or upgrading time over a ATM installed using the optimum area Always leave as much space as p...

Page 20: ...note that installing the ATM in the minimum servicing area may increase the servicing and or upgrading time over a ATM installed using the optimum area Always leave as much space as possible around t...

Page 21: ...Maximum 110 mm 4 33 in 1080 mm 42 52 in 110 mm 4 33 in 770 mm 30 31 in 375 mm 14 76 in 2 3 175 mm 6 89 in 375 mm 14 76 in 1520 mm 59 84 in 2026 mm 79 76 in 2352 mm 92 60 in denotes small 10 volume in...

Page 22: ...110 mm 4 33 in 70 mm 2 76 in 770 mm 30 31 in 2 1b 375 mm 14 76 in 2026 mm 79 76 in 326 mm 12 83 in 175 mm 6 89 in 2360 mm 92 91 in 110 mm 4 33 in 175 mm 6 89 in 450 mm 17 72 in 3 760 mm 29 92 in deno...

Reviews: