2
$"
emergency signals,
$"
signals of limit-stop positions,
$"
signals of ref-point switches.
The module is terminated mandatorily by instruction J1.
1.1.3 Execution of the Module :000
This module is used for serving classical PLC activities where no time dependence exists.
It may be interrupted by the task changer; as soon as its turn is on again, the execution can
be resumed at the point of interruption. The only exception is that the programmer "gives up"
the remaining time (with instruction J0) in favour of the rest of tasks. Instruction J0 will
cancel (suspend) the PLC task. After 20 ms, on completion of the activities mentioned in
Sections 1.1.2 and 1.1.1, the execution of the program will be resumed on the next turn at
the first instruction following module definition :000.