background image

PG-IRT1603

Infrared Forehead/Ear 

Thermometer

Thanks for buying and using this product, please read this 
manual carefully before use. 

User

 

manual

 

The USB Lighter Company, LLC

Address: 10940 Wilshire Blvd
STE 2010

 

Los Angeles, CA 90024

(949) 682-8817

Brand: NCT

Date: 

06-16-2020

       Rev : A/0

Summary of Contents for PG-IRT1603

Page 1: ...mometer Thanks for buying and using this product please read this manual carefully before use User manual The USB Lighter Company LLC Address 10940 Wilshire Blvd STE 2010 Los Angeles CA 90024 949 682 8817 Brand NCT Date 06 16 2020 Rev A 0 ...

Page 2: ...ease do not use this product for purposes other than body temperature measurement Do not use mobile phones close to this product Please do not use equipment that generates electromagnetic fields near the product Please do not disassemble or repair this device by yourself Please do not bend or stretch the device Please do not impact or drop this product Caution please refer to attached file Legend ...

Page 3: ...outh When the infrared sensor is damaged or dirty it may cause abnormal measurement results 3 If there is a temperature difference between the storage site and the measurement site please place it at room temperature measurement site for about 30 minutes before next measurement May result in incorrect measurement results 4 Please keep this product out of the reach of children Children can potentia...

Page 4: ...idue of this product at the end of the service life according to local laws and regulations Common sense about body temperature The comparison of different measurement methods The measured values are different if we use different measurement methods The WHO provides normal human body temperature reference values please see below table about the specific temperature difference The changes in human ...

Page 5: ...s low LCD shows sign and battery mark is always on which means you should replace the battery Warm prompts If storing the product for an extended period please remove the battery to assure longevity Battery fluids may harm the product and pollute our environment It is recommended to use alkaline batteries The way to handle a scrapped battery should match the requirements of local country governmen...

Page 6: ... Measurement result Note If you did not hear the beep sound this means that the temperature measurement has not yet been completed Please do not remove the thermometer probe from forehead at this time If you have disabled the sound indication it will have no sound indication 3 Object pattern measurement The installation of the head cover of forehead temperature has no influence to object pattern m...

Page 7: ...H When you operate this product the environment temperature cannot be greater than 104 F Er L This product has a lower operating temperature of 50 F When the ambient temperature exceeds this temperature point the LCD screen will display an error message Er L When you operate this product the environment temperature can not be lower than 50 F The measurement temperature is low The measurement posit...

Page 8: ...kV 4 kV 8 kV 15 KV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 30A m 50 60Hz Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Specifications of the product Product name Infrared Forehead Ear Thermometer Model number...

Page 9: ...odel PG IRT1603 Infrared Thermometer is used exceeds the applicable RF compliance level above the Model PG IRT1603 Infrared Thermometer should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the Model PG IRT1603 Infrared Thermometer d Over the frequency range 150 kHz to 80 MHz field strengths should ...

Page 10: ...ed Maximum output of transmitter W Separation distance according to frequency of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 7 GHz P V d 5 3 1 P E d 5 3 1 P E d 7 1 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated usin...

Reviews: