If you use or store this product beyond the range of
specified temperature and humidity, it
may
not reach
original performance specification.
Use environment: temperature: from
50
°
F
~
104
°
F
,
humidity: from 15%RH~93%RH
Storage environment: temperature: from -
13
°
F
~
131
°
F
,
humidity: from 0%RH~93%RH
Product introduction
04
03
Use caution
items
Intended use:
Infrared Forehead Thermometer intended
to measure human body temperature by measuring
forehead or
ear canal.
Scope of application:
Di
splaying the body temperature of
the measured object by measuring the heat radiation
of
the forehead or inner ear canal.
Features:
1.
Non-touching type infrared measurement of ear/
forehead temperature.
2.
Multiple colors and backlight display: White, Green,
Orange and Red.
3.
9 sets of memory values.
4.
Switch between
Fahrenheit
°F an
d Celsius°C.
(original setting is Celsius°C)
5.
Instant measurement within 1 second.
6.
The design is convenient and economical without
earmuff, which can save subsequent use costs.
7.
It has the function of sound on/off.
8.
When the
machine
is
idle
for
30 seconds,
the power will
turn off automatically.
Warm tip:
The measurement results of this unit at any time
are
meant to
be a reference, it can not replace the medical
diagnosis of professional doctor. If you have any
question
s
about
a
temperature result, please
consult a
doctor or physician
.
1. It is very dangerous for patients to judge and treat on their
only by measurement results, so please be sure to
own
doctor's instructions.
follow the
Self-judgment may lead to a worsening condition of
◆
patient.
2. Please do not touch with your hands or blow infrared
sensor with your mouth.
◆
When the infrared sensor is damaged or dirty, it may
cause abnormal measurement results.
3.
If there is a temperature difference between the storage
site and the measurement site, please place it at room
temperature (measurement site
)
for about 30 minutes
before next measurement.
◆
May result in incorrect measurement results.
4.
Please keep this product out of the reach of children.
◆
Children can potentially harm their ears with misuse
. If
a child
swallow
s
a
battery or the transparent cover,
please contact your doctor immediately.
5.
When measuring body temperature, please do not get
close to air conditioning.
◆
Avoid affecting the measurement accuracy.
6
.
Before and after use
:
U
se a cotton swab dipped
in
75% alcohol to wipe the probe surface. (If you see
stains, fog or water on the infrared sensor glass, please
use a cotton swab dipped
in
75% alcohol
to clean the
infrared sensor glass gently.)
7. The product suffers mechanical damage.
◆
There is a possibility that the measurement is not right.
Warning items
This unit is only used for human body temperature
measurement without use of disease diagnosis; it
cannot be used for emergency and continuous
measurement in surgery.
Parental guidance required for children under
the age of
twelve
.
Children's temperature should
only be measured under the guidance of an
adult.
P
atients
should not
diagnose
a
disease
and/or
get treatment by themselves on the bas
is
of
a
measurement result
. Please consult a physician
.
Children under 12 years of age and those who
cannot
express
their
thoughts
must be
supervised during use
.
Please do not use this product
if you
suffer from
otitis external, tympanitis
, or
other ear diseases.
Warning
◆
Do not use
toilet paper or facial tissue,
they risk
scratch
ing
the infrared sensor resulting in incorrect
measurement result
s
.
◆
Avoid cross-infection of ear disease
.