background image

5. CONNECTIONS:

PIN n°1: 

Service Battery negative pole (GROUND) (and negative cable of the 

photovoltaic panels)

PIN n°2: 

Positive cable of the photovoltaic panel n°1 (PF1)

PIN n°3: 

Positive cable of the photovoltaic panel n°2 (PF2)

PIN n°4:

 Service Battery positive pole (or positive common pole if there is a Power

Switch or an iManager)

PIN n°5:

 Start Battery positive pole

It is recommended to use cables with section of at least 4-6mm² 

6

CONNECTORS

Summary of Contents for SC300M

Page 1: ...SUN CONTROL MPPT Mod SC300M User Manual All the Energy you Need ...

Page 2: ...SUMMARY 1 INTRODUCTION 1 1 Safety Notes 1 2 Warnings 2 CHARACTERISTICS 3 INSTALLATION 4 CHARGING CURVE SELECTION 5 CONNECTIONS 6 HOW IT WORKS 7 TECHNICAL FEATURES 8 NOTES 9 WARRANTY 1 ...

Page 3: ...ease the fire risk During operation the device must be placed in a well ventilated area If the cables are damaged they must be replaced by a qualified technician to eliminate the risk of accidents 1 2 WARNINGS Keep the device out of the reach of children The device must be protected from sunlight or direct heat sources to prevent overheating DO NOT install the unit in a sealed environment otherwis...

Page 4: ...the devices previously distributed SC300M main characteristics Allows the charge of the service battery using solar panels with a nominal voltage of 12V Has two separate inputs for two solar panels of maximum power up to 150Wp for each with a nominal voltage of 12V The system has two outputs one for the service battery and one for the starter battery allowing a maintenance charge also on the start...

Page 5: ...evice pressing with moderation and caution the side tabs using a small screwdriver After removing the cover you have the full view of the PCB and the FASTON to connect the device to the solar panels and batteries so you can also select the charging curve and replace the fuses if necessary 4 1 2 3 4 5 Remote Display Optional Fuses Jumpers ...

Page 6: ...4 CHARGING CURVE SELECTION 5 ...

Page 7: ...itive cable of the photovoltaic panel n 1 PF1 PIN n 3 Positive cable of the photovoltaic panel n 2 PF2 PIN n 4 Service Battery positive pole or positive common pole if there is a Power Switch or an iManager PIN n 5 Start Battery positive pole It is recommended to use cables with section of at least 4 6mm 6 CONNECTORS ...

Page 8: ... a higher voltage than the battery The number of LED blinks followed by a pause indicates the charge phase running and ranges from 1 to 4 blinks If the photovoltaic panels generate electricity and the service battery is charged between 80 and 100 if the starter battery has a voltage lower than 12 5V and therefore needs a refresh the system activates the charge with a maximum current of 4A also on ...

Page 9: ...tage for start battery charging 12 5V Nominal voltage for each battery 12V Stand by current consumption 5mA Dimensions L123 x W108 x H50 mm Weight 0 40kg without cables If your Recreational Vehicle is in storage for a long time we recommend disconnecting the ground wire of the device to clear completely any current consumption that can inadvertently discharge the battery service 8 ...

Page 10: ...8 NOTES 9 ...

Page 11: ...roper installation use tampering or negligence shall not be covered by warranty Furthermore we assume no liability for any direct or indirect damages The SC300M returned even if under warranty must be shipped Freight paid and returned on as Freight collect The certificate of warranty shall be valid only if accompanied by a official receipt or delivery document Any dispute will be judged by the Cou...