NEO IP/GSM Technical Handbook
Document number: NE41 09002-02 v2.0
3.3.3
Undefined alarm types
All alarm types are not defined in every protocol. If an alarm type isn’t defined
the unit will try with the next position in the sequence to see if this position
holds another protocol. This will be done immediately. The same thing will
happen if a telephone number or alarm code is missing. In the Home phone
protocol, however, there is no requirement for any alarm code.
3.4
Alarm type groups
When an alarm type is decided, NEO IP/GSM have to decide what sequence to
use. This can be configured for 10 groups, see table below.
Group
Alarm types
Sequence
1. User alarms
User alarm from trigger
User alarm from button
User with battery failure
Reminder alarm
1,2,3 or 4
2. External alarms
Passive alarm
Door alarm
Bed alarm
Carpet alarm
1,2,3 or 4
3. Technical alarms
Accumulator alarm
Mains failure alarm
Mains OK indication
Battery alarm
Radio interference
Radio out of range
Radio within range
Inactivity
1,2,3 or 4
4. Smoke detector alarm
Smoke detector alarm
1,2,3 or 4
5. Assault alarms
Assault alarm
1,2,3 or 4
6. Presence alarms
Presence indication
Ready indication
Automatic ready indication
Action indication
Log call
1,2,3 or 4
7. Test alarm
Test alarm
1,2,3 or 4
8. Emergency alarm
Emergency alarm
1,2,3 or 4
9. Assistance alarm
Assistance alarm
1,2,3 or 4
10. User defined alarm
User defined alarm
1,2,3 or 4
To set the sequence for an alarm type group, see 8.8.1 Sequences for alarm types
The alarm call
19 of 56