NEO IP/GSM Technical Handbook
Document number: NE41 09002-02 v2.0
Static IP address, Gateway IP address and DNS server IP address.
If a static IP addres is to be assigned to the unit, enter the IP, Gateway and DNS
server IP adresses here. Check with the LAN administrator if unsure what infor-
mation to put in.
Subnet mask is usually 255.255.255.0, unless the LAN administrator states other-
wise.
8.15.2 SIP
Outbound proxy enable and Outbound proxy
Enter the ip address to the outbound proxy server if enabled.
SIP number enable
If SIP accounts are used, check this box and enter the information for at least ac
-
count 1 .
Account 1/2
Press the button to toggle between SIP account 1 and 2.
Number, Server, Username and Password
Enter the account information provided by the SIP operator.
Server port and Expire
These predefined values are default and should not be changed unless the SIP
operator states otherwise.
NEO IP/GSM port and RTP Port
These are the units own SIP/RTP communication ports.
Default values:
SIP: 5060
RTP: 16386
CIP PING enable
Is only used if the CIP protocol is selected as protocol type for an alarm source,
see 8.9.5 Protocol on page 42.
8.15.3 NEAT Web Service
This is the IP address of the NEAT Electronics web service and is used for surveil-
lance and updating.
NEO IP Programmer software