background image

12

PR.01

PR.02

PR.10

SC.01

SC.02

SC.30

Red

Green

Blue

White

Strobe

Time

Fade

(0~255)

(0~255)

(0~255)

(0~255)

(0~20)

(0~255)

(0~255)

EDIT

MENU

3.9

    EDITING CUSTOM PROGRAMS

EDIT CUSTOM

 Enter the

EDIT 

mode to edit the custom programs

PR.01

to

  

PR.10

.

 Each custom program has 30 steps that can be edited. 

 Each step allows the creation of a scene using RED 

Red

, GREEN 

Green

   BLUE 

Blue

, WHITE

White

,

  STROBE 

Strobe

, TIME

Time

 & FADE

  

Fade

.

SET

UPLD

ID

POW

ON

OFF

NORM

HIGH

REST

ON

OFF

RGBW

Off

Dim1

Dim3

Dim2

Dim4

Dim

MENU

3.10

    SPECIAL SETTINGS

SETTING

 Select

UPLD

to upload the custom programs from the current MASTER unit to 

    the SLAVE units.

 In order to activate the upload function the password must be entered.

 Password is the same as the main access password.

 When uploading the MASTER and SLAVE units will display YELLOW.

 If an error occurs when uploading the MASTER and/or SLAVE units will display RED.

 On successful uploading of the custom programs the MASTER and SLAVE units 

    will display GREEN.

 In order to reset custom modes to default values select 

REST

.

 Enter

ID 

in order to allow/disallow ID address function from the DMX512 

   controller.

  When 

RGBW

-- RGB TO WHITE is set to 

YES

, on RGB = 255,255,255,  the 

    color is perfect white as the actual RGB values are adjusted to make white. When it  
    is set to 

NO

,on  RGB = 255,255,255,  the  RGB values are not adjusted and the 

   output is most powerful. The 

RGB W

】’

s parameter can be adjusted in 

CAL2

.

 

Enter 

POW

 to choose the operation power  mode 

NORM

 or 

HIGH

   when it is normal mode, the power consumption is about 90W, while under high 
   mode, it is about 150W. 

 Enter 

Dim

 to select dimmer mode and dimmer speed. When DIMMER is set to 

  

Off

,  then RGBW and MASTER DIMMER are  linear. The Dim 1/2/3/4 are speed 

   modes of the non linear dimmer ,

Dim1

 is the faster, while 

Dim4

 is the slowest.

 The 

Dim

 setting here does not react on the the 

STAG

 mode.

NTSC
PAL

DV

Summary of Contents for NBL-P5403

Page 1: ...USER MANUAL Please Read Over This Manual Before Operating The Light Fixture...

Page 2: ...9 EDITING CUSTOM PROGRAMS 12 3 12 WHITES BALANCE 13 PART 1 PRODUCT GENERAL 1 1 1 PRODUCT INTRODUCTION 1 1 2 PRODUCT FEATURES 1 1 3 TECHNICAL SPECIFICATIONS 2 1 4 PHOTOMETRIC DATA 3 1 5 SAFETY WARNING...

Page 3: ...to be controlled from any DMX512 controller This product can be operated as a single unit or in multiple units for large applications 1 2 PRODUCT FEATURES LED FIXTURE 1 DIM1 4 RGBW Dimmer 0 100 Strob...

Page 4: ...MODULE Dimensions LED MODULE Voltage Rated Power 54pcs 14 x RED 14 x GREEN 14 x BLUE 12 x WHITE Weight LED Unit Output LED Cooling 3W Direct air convection 335 x 285 x 234mm 8 5Kg 100 250V 50 60Hz 200...

Page 5: ...UX 15 BLUE 1 2 3 0 1 2 3 1360 256 120 68 46 LUX 15 WHITE 1 2 3 0 1 2 3 2 4 6 8 10Distance m 4613 1204 552 326 230 LUX 15 RGB 1 2 3 0 1 2 3 2 4 6 8 10Distance m 11340 2885 1285 765 530 LUX 15 1 2 3 0 1...

Page 6: ...oducts The earth wire must always be connected to the ground Do not touch the power cables if your hands are wet ATTENTION This product left the place of manufacture in perfect condition In order to m...

Page 7: ...be connected in series 120V 7 units may be connected in series The LED MODULE can be mounted at any angle and in any position It is possible to further adjust the angle of the LED MODULE using the two...

Page 8: ...ettings menu on the fixture Each DMX Address may be used as many times as required Any DMX address in the range from 001 to 512 may be used Connect the DMX512 controller to the units in series 2 3 2 D...

Page 9: ...allows the user to collectively control the whole group of units at that DMX address by setting CH11 to 0 or to control each unit independently by first selecting the DMX address and then by using CH...

Page 10: ...or confirm the current function value scroll UP through the menu list or increase the value of the current function scroll DOWN through the menu list or decrease the value of the current function scr...

Page 11: ...255 0 255 0 255 0 20 0 255 0 255 SET UPLD ID POW ON OFF NORM HIGH KEY ON OFF STAG Arc 1 Arc 2 Ar1 d Ar2 s Ar2 d WT01 WT02 WT11 Red Green Blue White 0 255 0 255 0 255 0 255 MENU Red Green Blue White 0...

Page 12: ...and can be edited in EDIT mode STATIC COLOUR Combine Red Green Blue and White to create an infinite range of colors 0 255 Set the value of the Strobe 0 20Hz MENU Red Green Blue White 0 255 0 255 0 25...

Page 13: ...S 11 3 7 PERSONALITY PERSONALITY Enter the PERSONALITY mode to select DMX mode STAG Arc 1 Ar1 d Arc 2 Ar2 d Ar2 s or HSV 3 8 ID ADDRESS ID Enter the ID mode to set the ID ADDRESS D 001 512 DMX MENU ST...

Page 14: ...loading the MASTER and or SLAVE units will display RED On successful uploading of the custom programs the MASTER and SLAVE units will display GREEN In order to reset custom modes to default values sel...

Page 15: ...255 0 255 0 255 CAL1 MENU CAL1 Enter the CAL1 to select white color of different color temperature There are 11 pre programmed White colors can be edited by using Red Green Blue White 3 11 WHITES SET...

Page 16: ...90 110 130 29 49 69 89 109 129 149 150 169 170 200 201 205 206 210 211 215 216 220 221 225 226 230 231 235 236 240 RED UP GREEN 0 BLUE 100 RED 100 GREEN 0 BLUE DOWN RED 100 GREEN UP BLUE UP RED DOWN...

Page 17: ...UTO 10 0 40 41 70 71 80 81 90 91 100 101 110 AUTO 1 AUTO 2 AUTO 3 AUTO 4 AUTO 5 0 255 9 241 245 246 250 251 255 WHITE 9 8000K WHITE 10 8500K WHITE 11 10000K 6 DIMMER SPEED LINEAR DIMMER NON LINEAR DIM...

Page 18: ...D9 ID10 ID11 ID12 ID13 80 89 90 99 100 109 110 119 120 129 130 139 CHANNEL FUNCTION VALUE ID6 ID7 60 69 70 79 Arc 1 BLUE 1 2 0 255 CHANNEL FUNCTION VALUE 3 0 255 0 255 GREEN RED DIMMER SPEED LINEAR DI...

Page 19: ...FUNCTION VALUE 3 4 0 255 0 255 0 255 GREEN RED WHITE 5 0 255 MASTER DIMMER DIMMER SPEED LINEAR DIMMER NON LINEAR DIMMER 1 fastest 0 50 51 100 101 150 151 200 201 255 NON LINEAR DIMMER 2 NON LINEAR DIM...

Page 20: ...31 235 236 240 RED UP GREEN 0 BLUE 100 RED 100 GREEN 0 BLUE DOWN RED 100 GREEN UP BLUE UP RED DOWN GREEN DOWN BLUE 100 RED 100 GREEN 100 BLUE 100 WHITE 100 WHITE 1 3200K WHITE 3 4200K WHITE 2 3400K RE...

Page 21: ...a pulse strobe slow on fast off CH7 has priority over CH2 CH3 CH4 CH5 ID ADDRESS SELECTION CH9 is used to select the target ID address Each independent DMX address may have upto 66 independent ID addr...

Page 22: ...conncetions 3 Check the DMX signal receive IC 4 Check DMX address 1 The heat sensor resistance of LED board error 2 The temperature protection circuit on the display error When the surface temperatur...

Page 23: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 Front cover Rubber seal Clear glass Lens completed set LED PCB Heat sink Bracket Power connection board Display PCB Display protection metal plate Safety chain board...

Reviews: