039. BNC INPUT
**********************************************************************
Function:
This command sets the BNC Input for the incoming signal.
Command:
DFH 80H 60H 8CH 01H DATA00 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA00 BNC Select
01H
:
RGB
02H : Component
Response: At the time of a success
7FH 60H 80H 8CH 01H DATA00 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA00 BNC Select
01H
:
RGB
02H : Component
042. FREQUENCY REQUEST
**********************************************************************
Function:
This command inquires the Horizontal Frequency, Vertical Frequency, Horizontal Sync Polarity,
Vertical Sync Polarity, Mode and Resolution of the incoming signal.
Command:
1FH 80H 60H 26H 00H CKS
Response: At the time of a success
7FH 60H 80H 26H 0BH DATA00 to DATA0A CKS
Data Portion Contents
-------------------------------------------------------------------
Horizontal Frequency
DATA00 Integer Part
00H : 0 (No Signal: 00H)
:
FFH
:
255
DATA01 One Decimal Place
00H : 0 (No Signal: 00H)
:
09H
:
9
Vertical Frequency
DATA02 Integer Part
00H : 0 (No Signal: 00H)
:
FFH
:
255
DATA03 One Decimal Place
00H : 0 (No Signal: 00H)
:
09H
:
9
Horizontal Sync Polarity
DATA04
00H : -
01H
:
Positive
02H
:
Negative