00H : OFF
01H : MEMORY1
02H : MEMORY2
03H : MEMORY3
04H : MEMORY4
05H : MEMORY5
06H : MEMORY6
Response:
7FH 60H 80H 25H 01H CKS
Data Portion Contents
-------------------------------------------------------------------
DATA00:
01H : SET
02H : RESET
079. VOLUME GAIN REQUEST
**********************************************************************
Function:
This command inquires the volume gain for plasma.
Command:
1FH 80H 60H 0EH 00H CKS
Response:
DFH 60H 80H 0EH 01H DATA00 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA00:
VOLUME Gain
: 00H~2AH
00H
:
0
0FH
:
15
10H : 16
1FH
:
31
2AH : 42
FFH : MUTE
082. SEAMLESS SWITCH SELECT
**********************************************************************
Function:
This command selects the seamless switch function of the plasma.
Command:
DFH 80H 60H 7EH 01H DATA00 DATA01 DATA02 CKS
Data Portion Contents
-------------------------------------------------------------------
DATA00:
SEAMLESS SWITCH
01H :OFF
02H :ON
DATA01 :
SELECT1
01H : Video1
02H : Video2
03H : Video3
05H : DVD/HD1
06H : DVD/HD2( SCART1/SCART2)
07H : RGB1 / PC1
08H : RGB2 / PC2
0CH : RGB3 / PC3
0DH : HD3(SCART3)
DATA02 :
SELECT2
01H : Video1