5. Command Descriptions
----------------------------------------------------------------------
Precautions with Inscriptions:
(*3) Checksum : "CKS" inscription
This is the value of the lower 8 bits of the results calculated in
byte units from all the of the data up to the immediately preceding
data.
Example)
20H 81H 01H 60H 01H 00H 03H
+ + + + + + = CKS
(*4) Response error number
This is the value of the error number at the time of an error.
See "NAK" of "6-2. Data portion of response".
001. POWER ON
**********************************************************************
Function:
This command switches on the main power of the plasma.
Command:
9FH 80H 60H 4EH 00H CKS
Response: At the time of a success
3FH 60H 80H 4EH 00H CKS
Supplement:
The plasma doesn't accept another command during power on
processing.
002. POWER OFF
**********************************************************************
Function:
This command switches off the main power of the plasma.
Command:
9FH 80H 60H 4FH 00H CKS
Response: At the time of a success
3FH 60H 80H 4FH 00H CKS
Supplement:
The plasma doesn't accept another command during power
off processing.
003. INPUT SW CHANGE
**********************************************************************
Function:
This command switches the input terminal.