Section 4: Optional Equipment
4-30
Section 4: Optional Equipment
Aspila EX Hardware
VoIP Adapter
(Figure 4-33 - Figure 4-35)
The VoIP Adapter provides the ability to communicate through a LAN which is connected to a
16VOIPU or 8SHUBU PCB. The 16VOIPU or 8SHUBU PCB is required in order to communicate
with non-VoIP Aspila EX phones, as well as to place or receive outside calls.
This feature requires the use of a display system phone. As the VoIP Adapter is double the width of the
other phone adapters, only the VoIP Adapter can be used on a system phone. No other space is avail-
able for any additional adapter. When installing the VoIP Adapter, an AC/DC adapter is required for
local power or, for central power, one of the following must be used:
•
8SHUBU PCB
•
Power Supply Patch Panel (SN1604 PWRMS - NEC standard product)
•
Power Patch Panel (Cisco)
•
Catalyst PWR Series (Cisco)
If a separate software hub is used (and not the 8SHUBU PCB), it should be a 100Base/full duplex hub.
To avoid network problems and to ensure good voice quality, do not use a Repeater Hub/10Base.
Installing the VoIP Adapter:
1. Unplug the line cord from the system phone.
The line cord will not be needed with the VoIP Adapter as the system connection will be
made through the LAN connection.
2. Using a flat-head screwdriver, remove the plastic punch-out piece covering the connector.
Note the position of the connector on the VoIP Adapter in order to remove the correct
piece (the adapter uses the connection on the side of the phone which has the line cord con-
nection.
3. Set the dip switches on the top of the VoIP adapter to the required position. The setting is
dependent upon the type of power supply being used.
•
The SW1 settings are “1” when using an AC/DC adapter, 8SHUBU, or SN1604 PWRMS,
“2’ when using Cisco’s Power Patch Panel or Catalyst PWR panel.
Figure 4-33: SETTING THE DIP SWITCHES