Section 2: PCB Installation and Startup
2-4
Section 2: PCB Installation and Startup
Aspila EX Hardware Man-
3. Insert the PCB within the guide rail and push the PCB securely into position. After installing
all the PCBs, the PCB retaining bar should be moved back into position and the screws should
be tightened.
Figure 2-2: INSERTING PCBS
4. Set the run/block switch to
RUN
. The Status LED starts flashing when the PCB starts processing
(15 seconds).
Removing an Extension or Trunk PCB
To remove an extension/trunk PCB with the system running:
1. Set the run/block switch to
BLOCK.
2. When the STATUS LED stops flashing, all extensions/trunks are idle.
3. Remove the PCB by lifting the white pull clip on the top of the PCB and pull the PCB out.
Uninstalling a PCB Slot Through Software
The installer can turn off (busy out) and delete (remove from software) PCB slots in the Main and
Expansion Cabinets in programming for port re-numbering purposes or to replace it with a different
type of PCB. Deleting a PCB may affect PCB slot programming capability. Refer to Program 90-05 in
the Software Manual for further details.