Chapter 1 Overview
Read this chapter if you use the Additional DAC Battery (called BBU below) for the first time.
This chapter describes the characteristics and configuration of the BBU, and outlines the additional battery
installation job.
1. BBU Characteristics
The BBU is an additional battery exclusively used for the Disk Array Controller (SAS).
Connecting the BBU to the disk array controller can prevent data from being lost due to an unforeseen
accident, including instantaneous power interruption (in the WriteBack mode).
Backup (up to 72 hours ) of the data in the disk array controller cache memory.
Improvement of reliability in WriteBack mode.
Use of rechargeable NiMH battery.
2. Specifications
Item Specifications
Remarks
Maximum data backup time
72 hours
Full charge
Outer dimension (mm)
39 (width) × 133 (depth) × 9 (height)
Weight
About 0.10 kg
Battery capacity
4.22 Wh
Normal operation
Temperature
10
°
C - 35
°
C
Operating
environment
Humidity
20% - 80%
Without condensation
Temperature
0
°
C - 35
°
C
Storage
environment
Humidity
20% - 80%
Without condensation
Life (battery back)
About 2 years
Varies depending on the
operating environment and
the boundary conditions
Summary of Contents for BBU