Displays connected via LAN need to be assigned an IP address so that they can be remotely accessed. Each
display with a LAN interface has a default IP address of 192.168.0.10. This address must be changed in order to
avoid conflicts when other displays are connected to the LAN. When the LAN RESET operation is performed on a
display’s OSD, the IP address will be reset to the default value.
It is recommended to assign the IP address of a display by connecting a PC directly to the LAN port on the display,
or via a LAN HUB while no other devices are connected.
If the PC being used to set the IP address of the display is not currently set to access the subnet that includes the
display’s defaults IP address, it will be necessary to temporarily modify the network settings in order to assign the
PC a temporary IP address and subnet so that the display can be accessed. Once the display has been configured
the PC network settings should be restored.
Open the
Network Settings properties
of the PC, and select
Internet Protocol
TCP/IP
in the list, then click the
Properties
button.
Next enter a temporary IP address for the PC, such as 192.168.0.255, and a
subnet mask of 255.255.255.0. Click
OK
and close the Network Settings.
Next open a web browser and go to the URL of the display’s web server by entering:
http://192.168.0.10
This should display the display’s MONITOR NETWORK SETTINGS page.
8
assigning an ip address