63
6. Appendix
• Timing chart of GPIO control
Off at least 500 ms
at least 500 ms
8-27
5-24/6-25/7-26
time
Execute
Select Preset Button
off
on
off
on
Example of Select Preset Button
approx. 200 ms
Off at least 500 ms
at least 500 ms
approx. 200 ms
5-24/7-26
6-25/8-27
time
Execute
Image douser (Douser) ON
off
off
on
on
Example for turning the image douser (Douser) on
Off at least 500 ms
at least 500 ms
approx. 200 ms
5-24/6-25
7-26/8-27
time
Execute
Lamp On
off
off
on
on
Example of Lamp On